3.2.3. Wired Access to the OMT on NPRU
It is different to get access to WebOMT through NPRU in addition to change Link speed & Duplex. To set up
wired access to the OMT from NPRU, use the following procedure:
1. Connect a PC to NPRU with a network cable in the GE port in the front panel.
2. Change the TCP/IP properties:
e) Click Network Connections
f) Click Local Area Connection Properties
g) Click TCP/IP Properties
h) Change parameters as indicated:
IP address: 11.7.1.2 (the last number is changeable except for 11.7.1.1)
Subnet mask: 255.0.0.0
Default Gateway: 11.7.1.1
3. Change Link Speed & Duplex to 100Mbps Full Duplex in Advanced of Network Connection
Properties (see Figure 3-4)
4. Check the status of the Local Area Connection and confirm the connection is connected.
5. Open a browser window and enter the default gateway in the navigation bar to access the WebOMT
page by using 11.7.1.1 as the default gateway.
Note: Wired access port (GE port) is default set to be disable for the devices security. The Access Switch
must be pre-turned on in the NPRU OMT (Maintenance -> Engineering -> Phy Debug Access) before using
the wired access to the NPRU.