Submittal Sheet
SlabHeat Cable is a complete heating cable consisting of a series
resistance heating cable and a single power lead for easy single-point
connection. The heating cable length cannot be cut to fit.
SlabHeat
™
Electric Indoor Heating Cable
For Residential and Commercial Applications
Job Name
–––––––––––––––––––––––––––––––––––––––––––
Contractor
––––––––––––––––––––––––––––––––––––––––––––
Job Location
–––––––––––––––––––––––––––––––––––––––––
Approval
–––––––––––––––––––––––––––––––––––––––––––––
Engineer
–––––––––––––––––––––––––––––––––––––––––––––
Contractor’s P.O. No.
–––––––––––––––––––––––––––––––––––
Approval
–––––––––––––––––––––––––––––––––––––––––––––
Representative
––––––––––––––––––––––––––––––––––––––––
ES-ST-SlabHeat
SunTouch product specications in U.S. customary units and metric are approximate and are provided for refer-
ence only. For precise measurements, please contact SunTouch Technical Service. SunTouch reserves the right to
change or modify pr
oduct design, construction, specications, or materials without prior notice and without incurring
any obligation to make such changes and modications on SunTouch products previously or subsequently sold.
This Engineering Sheet is not intended to provide full installation instructions
and safety information. In order to avoid property damage or injury, please
refer to the complete installation manual and product safety information
provided with the product.
Never cut the heating cable or damage it in any way. Use only the attachment
methods as described in the Installation Manuals for SunTouch SlabHeat as
other methods may damage the heating element.
Specifications
UL Listed for U.S. under UL Standard 1673 and Canada
under CAN/CSA C22.2 No. 130.03.
Listing file number E185866.
Supply Voltage
120VAC, 1-phase
240VAC, 1-phase
Maximum Heater Current 15 Amps
Maximum Circuit Load* 15 Amps
Wire Spacing
4"
6"
Power Lead 10' long, 14 ga.
Outer Jacket Polyurethane
Ground Plane Full Coverage Braided Copper
Insulation ETFE
Heating Elements Dual, Copper
*GFCI (Ground Fault Circuit Interrupter) is required for each circuit.
Heating Density
120VAC 240VAC
4" Wire
Spacing
15 W/sf
51 BTUh/sf
6" Wire
Spacing
10 W/sf
34 BTUh/sf
Application Parameters
Min. Bend Radius 1 inch
Max. Exposure Temperature
(continuous and storage)
194ºF (90ºC)
Min. Installation Temperature 50ºF (10ºC)
Application
SlabHeat cables are only designed for use in an interior space embedded
in concrete.
SlabHeat Cables are available in various lengths with
voltage options of 120 VAC and 240 VAC.
Installation Guidelines
Determine a time to install the cable when equipment, heavy tools, and site
traffic will be minimal. Apply the surfacing courses over the cable the same
day the cable is installed.
If installing cable in the upper layer of a two-stage concrete slab, the cable
should be completely ready for the second stage. There is limited time
between stages, as the slab should not be allowed to fully cure. Therefore,
lay out the cable and tie it to rewire that can be quickly lifted into place
after the first stage is laid.
Inspect the area and remove any sharp objects.
Install in temperatures at least 50°F (10°C).
For a new concrete slab, when a run of cable exceeds 20 feet, an additional
downward U-shaped loop with a 1 to 2 inch radius, should be added to help
minimize possible damage to the cable from thermal expansion.
Polyurethane Outer Jacket
Dual Copper Heating Elements
Full Coverage Braided
Copper Ground Plane
ETFE Insulation
Foil Shield