TapeMat Installation Manual

5 of 36 © 2014 Watts Water Technologies
Installation must be performed by qualified personnel, in accordance with local codes and
standards. A licensed electrician is recommended.
Phase 1 - Preparations
ALWAYS make sure all electrical work is done by qualified persons in accordance with local
building and electrical codes, Section 62 of the Canadian Electrical Code (CEC)
Part I, and the National Electrical Code (NEC), especially Article 424.
ALWAYS use copper only as supply conductors to the thermostat. Do not use aluminum.
ALWAYS seek help if a problem arises. If ever in doubt about the correct installation procedure
to follow, or if the product appears to be damaged, the factory must be called before
proceeding with the installation.
Before installing TapeMat, make sure to fully inspect the products and carefully plan the site.
Items Needed
Materials:
SunStat thermostat control with floor sensor.
SunStat Relay control (if required)
Control electrical box (UL Listed, extra deep, see control instructions for size and type required)
Junction electric box (if required, see Step 2.2)
Wire nuts (Must be UL Listed and proper size)
Flexible or rigid conduit (if required, see Step 2.4, must be UL Listed and proper size)
12-gauge or 14-gauge electrical wiring cable (consult local code)
Nail plate (see Step 3.8)
Tools:
Digital multi-meter for ohms testing; must read up to 20,000 ohms to measure sensor
Drill with 1/2" & 3/4" bits
Hammer and chisel
Hot glue gun and hot glue (craft grade)
• Wire strippers
• Phillips screwdriver
• Fish tape
• Hole saw
Floor covering installation tools
Floor sensor is
included in the
SunStat thermostat
packaging. This must
be installed in the
floor with the mat.