Dynamic ☆ Read and retain these instructions for future reference Dynamic 6.0 plus Dynamic 8.
SPECIFICATION Model no. Cooling capacity Power/Ampere consumption for cooling* Air volume (max. speed) Humidity removal capacity Power supply Recommended room size Compressor Power supply Refrigerant Refrigerant load* Fan speed Timer Working temperature, thermostat Net Weight Dimension Dynamic 6.0 plus Dynamic 8.0 plus 6000 BTU/h 680 W / 3,0 A 8000 BTU/h 800 W / 3.
BEFORE USE CAUTION ! Make sure the unit is connected to a earthed, power supply of the correct rating. (Please refer to the rating label locating at the back side of the unit.) Do not use this product for functions other than those described in this instruction manual. Always place the unit on a stable ground base. (FIG.1) The unit must always stand or be transported in a vertical position. Do not cover or obstruct the appliance’s inlet and outlet Grilles. (FIG.
29 BEFORE USE If the electrical socket is different from the plug, have a professionally qualified electrician replace the socket with a suitable one. Avoid the use of adapter plugs, multiple sockets and / or extension leads. If their use is necessary, ensure they conform to current safety regulation. Do not pull the supply cable or place it near a source of heat: always unroll it completely to avoid dangerous overheating.
Parts Front 1. 2. 3. 4. 5. 6. Back Display window Control panel Buttons Air outlet Carrying handle Caster 7. Cord storage 8. Air filter 9. Air inlet 10. Exhaust air outlet 11. Air inlet 12. Water stopper/drainage point Accessories 13. Outward adaptor - for insertion over hose and into foam strip (or into hole in the wall/window). 14. Exhaust hose 15. Foam strip - for filling the open window space and with hole for connection to exhaust hose. 16. Foam strip - for filling the open window space 17.
INSTALLATION Installation of the exhaust pipe This unit is a PORTABLE AIR CONDITIONER. It can be moved from room to room, so the cooling can follow you anywhere. The mounting is easy, beneath a window or wall. Please refer to either of the following steps: 1. Using the foam strips • • Connect the supplied foam strips with the exhaust pipe to let hot air flow to the outside. If necessary cut off the extra part to fit the window.
INSTALLATION Mounting of the exhaust pipe 1. Use only the hose provided and clip exhaust hose to the back of the air conditioner. It is recommended that you use the hose in the shortest possible length. 2. Avoid kinks and bends in the exhaust hose as this will cause expelled moist air to build up causing the unit to overheat and shut down. FIG. 8 FIG.9 FIG.10 WARNING! The length of the exhaust pipe is specially designed according to the specification of this product.
Control panel , Fig. 12 1. 2. 3. 4. 5. 6. 7. 8. ON/OFF (power) button Timer ‘Temperature up' button Indicator for compressor “Water Full” indicator ‘Temperature down' button Speed (ventilation)button Mode (function) option button 9. Fan mode indicator 10. Cooling mode indicator 11. Automatic mode indicator 12. High ventilation indicator 13. Low ventilation indicator 14. Display window 15. Receiver for remote control 16. Timer operation indicator Turning ON/OFF 1.
1. Press SPEED button to choose the ventilation speed you need, high or low. The indicator of high or low ventilation will light on at the same time. 2. If the unit is in AUTO mode, it will choose the ventilation speed automatically according to the ambient temperature (the related indicators will light on), at this time, the speed switch is invalid. Setting timer 1. 2. Press TIMER button to set the operating hours you desired (1 to 12 hours, the timer indicator will light on).
NOTICE ! 1. To prolong the compressor's life, after switch-off of the unit, please wait for 3 minutes (at least) before re-switch. 2. The cooling system will switch off if the ambient temperature is lower than the set one. The ventilation, however, keeps working on the set level. If the ambient temperature rises above the selected level, the cooling will return to work. Installation of the carbon filter 1. 2. 3. 4. Remove the filter frame from the unit.
During the process of cooling some water will be extracted from the air into the unit. If the reservoir is full, both the compressor and motor will stop and the units would buzz (you can press any button to stop the buzz), only the fan runs to circulate the air. The W.F. indicator will flash to show you. To make the cooling work again, please empty the water by one of the following ways: 1. Turn off the air conditioner and avoid moving it while full. 2. Position a container (a water tray e.g.
Always unplug the air conditioner from the mains before cleaning. Cleaning the housing Use a soft, damp cloth to wipe the body clean. Never use aggressive chemicals, gasoline, detergents, chemically treated cloths, or other cleansing solutions. These all could possibly hurt the cabinet. Cleaning the filter Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt from the filters and then rinse thoroughly under running water (no hotter than 40ºC). Dry thoroughly before replacing.
The air conditioner does not run The machine seems to do little The machine seems to do nothing Too noisy Is the machine plugged in? Is the house power supply on? Is the ‘FULL WATER’ indicator flashing? (If so, empty the condensed water) Is the room temperature in the working range? Is there direct sunshine? (Please put down the curtain.