Dynamic ☆ Read and retain these instructions for future reference Dynamic 2.
SPECIFICATION Model no. Cooling capacity Power/Ampere consumption for cooling* Air volume (max. speed) Humidity removal capacity Power supply Recommended room size Compressor Power supply Refrigerant Refrigerant load* Fan speed Timer Working temperature, thermostat Net Weight Dimension Dynamic 2.
BEFORE USE CAUTION ! This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. Make sure the unit is connected to an earthed, power supply of the correct rating.
BEFORE USE If the electrical socket is different from the plug, have a professionally qualified electrician replace the socket with a suitable one. Avoid the use of adapter plugs, multiple sockets and / or extension leads. If their use is necessary, ensure they conform to current safety regulation. Do not pull the supply cable or place it near a source of heat: always unroll it completely to avoid dangerous overheating.
Parts Front 1. 2. 3. 4. 5. 6. Back Display window Control panel Buttons Air outlet Carrying handle Caster Accessories 13. Outward adaptor - for insertion over hose and into foam strip (or into hole in the wall/window). 14. Exhaust hose 15. Foam strip - for filling the open window space and with hole for connection to exhaust hose. 16. Foam strip - for filling the open window space 17. Round cap for filling the hole in wall/window. 18. Drain tube for continuous drainage 19. Active carbon filter 20.
INSTALLATION Installation of the exhaust pipe This unit is a PORTABLE AIR CONDITIONER. It can be moved from room to room, so the cooling can follow you anywhere. The mounting is easy, beneath a window or wall. Please refer to either of the following steps: 1. Using the foam strips • • Connect the supplied foam strips with the exhaust pipe to let hot air flow to the outside. If necessary cut off the extra part to fit the window.
INSTALLATION Mounting of the exhaust pipe 1. Use only the hose provided and clip exhaust hose to the back of the air conditioner. It is recommended that you use the hose in the shortest possible length. FIG. 8 2. Avoid kinks and bends in the exhaust hose as this will cause expelled moist air to build up causing the unit to overheat and shut down. FIG.9 FIG.10 WARNING! The length of the exhaust pipe is specially designed according to the specification of this product.
Handling of electronic type Control panel , Fig. 12 1. 2. 3. 4. 5. 6. 7. 8. ON/OFF (power) button Timer ‘Temperature up' button Indicator for compressor “Water Full” indicator ‘Temperature down' button Speed (ventilation)button Mode (function) option button 9. Fan mode indicator 10. Cooling mode indicator 11. Automatic mode indicator 12. High ventilation indicator 13. Low ventilation indicator 14. Display window 15. Receiver for remote control 16. Timer operation indicator Turning ON/OFF 1. 2. 3.
Setting ventilation speed 1. Press SPEED button to choose the ventilation speed you need, high or low. The indicator of high or low ventilation will light on at the same time. 2. If the unit is in AUTO mode, it will choose the ventilation speed automatically according to the ambient temperature (the related indicators will light on), at this time, the speed switch is invalid. Setting timer 1. 2.
Installation of the carbon filter 1. 2. 3. 4. Remove the filter frame from the unit. Remove the active carbon filter from its plastic bag. Insert the active carbon filter into the back of the unit. Re-fit the filter frame inside the unit.
DRAINAGE During the process of cooling some water will be extracted from the air into the unit. If the reservoir is full, both the compressor and motor will stop and the units would buzz (you can press any button to stop the buzz), only the fan runs to circulate the air. The W.F. indicator will flash to show you. To make the cooling work again, please empty the water by one of the following ways: 1. Turn off the air conditioner and avoid moving it while full. 2. Position a container (a water tray e.g.
MAINTENANCE Always unplug the air conditioner from the mains before cleaning. Cleaning the housing Use a soft, damp cloth to wipe the body clean. Never use aggressive chemicals, gasoline, detergents, chemically treated cloths, or other cleansing solutions. These all could possibly hurt the cabinet. Cleaning the filter Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt from the filters and then rinse thoroughly under running water (no hotter than 40ºC).
FAULT CHECK LIST The air conditioner does not run The machine seems to do little The machine seems to do nothing Too noisy Is there direct sunshine? (Please put down the curtain.