Conversion Instruction
Conversions Between Natural Gas and Propane
Before proceeding, make sure you have cleared away from grilling area any loose debris and secure a small box to
place each screw in as you remove them. Locate a chair that has arm supports or other platform, and place this in
front of grill giving you an elevated position to set the grills control panel after removal, this way you do not need to
remove any wires, or other hoses. In step "4", there are two pins that are holding the control panel in place, you will
need to wiggle the control panel for it to drop down, sometimes angling it then pulling down will also release it were
the valves are inserted in burners.
PAGE 3 OF 8
1.
2.
3.
1.
Remove Drip Pan
Unfasten Screw
Remove Left &
Right Screws
5.
While removing Control Panel Assembly, it may be necessary to tilt back and forth,
while pulling down, as there are two PINS holding control panel to Grill Frame.
4.
4. Remove the Small Center Knob
After removing the center small knob, the same one for
the back Infra-red Burner, also remove ONLY the Top and
Bottom Screws. This will release valve from control
panel, but still keep it afixed to the gas manifold pipe.
5. Slide out Control Panel
Grip base of control panel firmly, and first pull down and
out releasing the two pins inserted into grill control panel
frame. (See illustration below)
Only Remove
Top & Bottom
Screws
IMPORTANT!!! - BEFORE BEGINGING CONVERSION, GAS MUST BE TURNED OFF
Remove LP
Regulator