How to Guide

GAS INSTALLATION – Natural Gas Installation
Natural Gas Burners are designed to operate on Natural Gas ONLY, at a pressure regulated at 4”
water column (W.C.) when equipped with the correct natural gas orifices on the valves and a NG
regulator on the supply line regulated at the residential meter.
10
Natural Gas Supply Connection and Disconnection
1. Make sure all burner valves are in the “OFF” position.
2. To connect-push back sleeve of socket, insert Plug release sleeve. Push Plug until sleeve snaps forward
locking Plug in Socket. (THIS TURNS GAS AUTOMATICALLY).
3. To disconnect: Push sleeve back and pull out plug. (THIS AUTOMATICALLY SHUTS OFF GAS)
4. Connected hose assembly shall be of adequate length and capacity for intended application. Final
assembly must be tested for leaks.
Natural Gas Regulator & 18” Hose is packed
separately inside Burner marked for NG