Spec Sheet
OVERHEAD STRUCTURE
(C) MINIMUM 5' FEET FROM
COUNTER TO BOTTOM
EDGE OF OVERHEAD STRUCTURE
(E) 2 VENTS IN "HIGH"
POSITION FOR NATURAL GAS
(F) 2 VENTS IN "LOW"
POSITION FOR LIQUID PROPANE
(D) MAINTAINE 24" CLEARNACE
FROM ALL COMBUSTIBLE
MATERIALS
(H) ISLAND
STRUCTURE MUST BE
NON-COMBUSTIBLE
(B) 8' FEET MINIMUM
CLEARANCE FROM FLOOR TO
OVERHEAD STRUCTURE
(G) NON-COMBUSTIBLE
BARRIER SHIELDING
ENCLOSED STRUCTURE
IMPORTANT! REFER TO PRODUCT MANUAL FOR A COMPLETE
DESCRIPTION OF INSTALLATION, PLACEMENT AND CUT-OUT.
SPECIFICATIONS
A
MUST USE VENT HOOD ABOVE GRILL FOR ENCLOSED
STRUCTURES
B
MIN. CLEARANCE FROM FLOOR TO
OVERHEAD STRUCTURE
8 FEET
C
MIN. DISTANCE FROM COUNTER TO
BOTTOM OF OVERHEAD STRUCTURE
5 FEET
D
MINUMUM CLEARNACE FROM ALL
COMBUSTIBLE MATERIALS
24 INCHES
E
2 VENTS IN "HIGH" POSITION FOR NATURAL GAS
F
2 VENTS IN "LOW" POSITION FOR LIQUID PROPANE
G
Install Non-Combustible Barrier Shielding, Stainless
Steel Sheet is recommended.
H
ISLAND STRUCTURE MUST BE NON-COMBUSTIBLE
OTHERWISE YOU MUST USE GRILL JACKET UNDER ALL
GAS APPLIANCES, WE RECOMMEND SUNSTONE'S
DESIGNER SERIES CABINET ISLANDS
BODILY INJURY: Failure to maintain required clearances creates a
fire hazard that may result in property damage or serious personal injury.
ATTENTION: Always take a leak test before lighting the grill to
prevent a possible fire or explosion. Never store a spare propane cylinder in
the vicinity of this Grill, or in the vicinity of any other potential heat source.
Never attempt to attach this grill to the self-contained LP gas system. Do not
use grill until leak testing.
ATTENTION: Never operate the grill unattended.
IMPORTANT: When Igniting the Grill – Always keep the cover
removed.
PAGE 5
(A) Must use Vent
Hood above Grill