Insert the regulator inlet into the tank valve and turn the coupling nut clockwise until the coupler
tightens up (see picture). Do not over tighten the coupler. Turn the main tank valve on and turn the
burner control valves on the unit to the “HIGH” position for about 20 seconds to allow the air in the
system to purge before attempting to light the burners.
WARNING: Always take a leak test before lighting the grill to prevent a possible fire or explosion.
Never store a spare propane cylinder in the vicinity of this side burner, or in the vicinity of any other
potential heat source.
LP Gas Supply Cylinder Disconnection
1. Turn the burner valves off.
2. Turn the tank valve off. (Turn clockwise to stop).
3. Detach the regulator assembly from the tank valve by turning the quick coupling nut
counterclockwise.
LP Tank Removal, Transport and
Storage
- Turn OFF all control knobs and LP tank valve. Turn coupling nut counterclockwise by hand only - do
not use tools to disconnect. Lift LP tank wire upward off of LP tank collar, then lift LP tank up and off
of support bracket. Install safety cap onto LP tank valve. Always use cap and strap supplied with
valve. Failure to use safety cap as directed may result in serious personal injury and/or property
damage.
- A disconnected LP tank in storage or being transported must
have a safety cap installed (as shown). Do not store an LP
tank in enclosed spaces such as a carport, garage, porch,
covered patio or other building. Never leave a LP tank inside
a vehicle which may become overheated by the sun.
- Do not store LP tank in an area where children play.
LP Tank
Filling
- Use only licensed and experienced dealers.
- LP dealer must purged tank before filling.
- Dealer should NEVER fill LP tank more than 80% of LP tank volume. Volume of propane in tank will
vary by temperature.
- A frosty regulator indicates gas overfill. Immediately close LP tank valve and call local LP gas dealer
for assistance.
- Do not release liquid propane (LP) gas into the atmosphere. This is a hazardous practice.
- To remove gas from LP tank, contact an LP dealer or call a local fire department for assistance.
Check the telephone directory under “Gas companies” for nearest certified LP
dealers.
LP Tank
Exchange
- Exchange your Type 1 cylinder with OPD safety feature-equipped ONLY.
- Always keep new and exchanged LP tanks in upright position during use, transit or storage. Leak