Product Manual
Form #43471010
-30- Mar 09
30 seconds after
startup, does the
amber monitoring light
come on?
Yes
No
while the amber light
is on, through the
inspection window, is
there a flame visible?
Yes
No
Is the knob on the gas
valve in the ON
position? (Its shipped
from the factory at
OFF position)
Yes
No
Is there 24 vac across
25V(GND) and 25V
terminals on ignition
module?
Replace the amber
light.
Are the two wires to
the amber light
securely hooked to
the terminals of the
gas valve?
Does the amber light
stay on until call for
heat ends?
Yes
No
Repair connection.
Troubleshooting
continued on the next
page.
Move the red wire to
air switch terminal
NO.
Is the red wire from
ignition module 25V
terminal hooked to air
switch terminal NO?
Restart
troubleshooting.
Yes
No
Turn the knob to ON
position.
No
30 seconds after
startup, check the
voltage across valve
terminals on ignition
module. Is it 24 vac?
No
Yes
Move the white wire
to the transformer
terminal.
Is the fuse OK on
ignition module?
Yes
No
Replace the fuse.
Yes
Is there a spark
across igniter/sensor
gap?
Yes
No
Is the ground wiring
between the ignition
module and the
control box OK?
No
Yes
Adjust the electrode
tip into the flame.
Is the ceramic
insulator OK on the
spark electrode?
No
Yes
Replace the spark
electrode.
Is the spark gap
3/16?
No
Yes
Adjust the spark gap
to 3/16.
Replace the ignition
module & ignition
cable.
Spark stops when
burner is lit?
Yes
No
Is the electrode tip
directly in the flame?
No
Yes
Replace the spark
electrode.
Is there continuity
between electrode
sensor and ground
stud in the cabinet?
No
Replace the spark
electrode.
Troubleshooting
continued from the
previous page.
Fix the grounding
problem.
Replace the ignition
module.
Yes
No
Is the white wire from
ignition module
25V(GND) hooked to
transformer?
Yes
No
Yes
Check the flame
current at the ignition
module. Is it over
1.5mA with flame?
No
Yes
Replace ignition
module.
See next page for
troubleshooting
sequence.
Restart
troubleshooting.