Product Manual

Form #43219020
June 09 6
6) SG SERIES DIMENSIONS
15-3/4 (40cm)
9 (23cm)
Hanging
Dimension
12 (30cm)
Hanging Dimension
(Typical all Models)
1-BURNER UNIT
21/5/8 (55cm)
14-7/8 (38cm)
Hanging
Dimension
26-1/2
(67cm)
2-BURNER UNIT
3-BURNER UNIT
27-1/2 (70cm)
20-3/4 (53cm)
Hanging Dimension
26/1/2
(67cm)
26-1/2
(67cm)
TYPICAL SIDE VIEW
Gas Manifold
Assembly
Ignition Control
Assembly
3/8 (1cm) Diameter Hole
for Hanging
(Typical 4 Places)
7-3/4
(20cm)
26-1/2 (67cm)
Reflector
Assembly
33-3/8 (85cm)
26-5/8 (68cm)
Hanging Dimension
26-1/2
(67cm)
4-BURNER UNIT
7) HANGING
Always suspend from a permanent part of the building structure that can
support the total force and weight of the heater.
Never use the heater to support a ladder or other access equipment.
Improper suspension of the infrared heater may result in collapse and being
crushed.
Failure to do so may result in death, serious injury or property damage.
SUSPENSION HAZARD
The heater can be mounted with the reflector horizontal or angled up to 35º from horizontal. When the heater is to be angle
mounted, make sure the gas manifold assembly is on the lower side of the heater. Coil chains (No. 2 or larger) or rigid
supports may be used to mount the heater, which must be suspended from a permanent structure with adequate load
capacity. The gas manifold assembly tube must be level, and for angled mounting, it must be at the LOWER end of the
heater. All “S” hooks and eyebolts must be manually crimped closed by the installer.
8) GAS CONNECTIONS AND REGULATION
An approved connector, suitable for the environment of equipment
usage, is required. Visible or excessive swaying, flexing and
vibration of the gas connections must be avoided to prevent
failure. Neither the gas pipe nor the connector shall be placed
in the flue discharge area. In no case shall the gas supply
support the weight of the heater.
Failure to do so may result in death, serious injury or property
damage.
FIRE AND EXPLOSION HAZARD