Installation and Operating Guide

-9-
1. STOP! Read the safety information above.
2. Make sure manual shutoff valve is fully open.
3. Turn thermostat control knob clockwise ( )
to the “OFF” position.
4. Wait ten (10) minutes to clear any gas.Then smell
for gas, Including near the floor. If you smell gas,STOP!
Follow “B” in the safety information above. If you don´t
smell gas, go to the next step.
5. Find pilot attached to the main burner which is located
at bottom of combustion chamber.
6. Turn knob on gas control counterclockwise ( )
to “Pilot” position.
Pilot
Burner
Pilot
Burner
7. Depress and hold down the thermostat control knob.
While holding the control knob down, push the
piezo ignitor button repeatedly to light the pilot.
Continue to hold the control knob in for about 30 seconds
after the pilot is lit.Release knob and it will pop back up.
Pilot should remain Iit. If it goes out repeat steps 3 through 7.
If knob does not pop up when released,stop and
inmediately call your service technician or gas supplier.
If the pilot will not stay lit after several tries, turn the gas
control knob to the “OFF” position and call your service
technician or gas supplier.
8. Attention! Gas control has an INTERLOCK device.
When the pilot is initially lit and the safety magnet in energized
( pilot stays “ON”) the INTERLOCK latching device becomes
operative.
If the gas control is turned to the “OFF” position or gas flow to
the appliance is shut off, the pilot cannot be relighted until the
safety magnet is de-energized (approximately 60 seconds ).
There will be an audible “click” when the safety magnet in
the gas control is de-energized.
Pilot can now be relighted. Repeat steps 3 through 7.
9. Turn gas control Knob counterclockwise ( ) to the
desired heating level from “LO” to “HI”.
LO
P
OFFHI
LO
P
OFFHI
LO
P
OFFHI