Installation Instructions
8
SunRite | Gas-Fired Infra-Red Tank Top Heater Operating Instructions and Owner’s Manual
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
WARNING
AirQualityHazard
•Donotusethisheaterforheatinghumanlivingquarters.
•Useofdirect-firedheatersintheconstructionenvironmentcanresultinexposuretolevelsofCO,CO2,andNO2con-
sideredtobehazardoustohealthandpotentiallylifethreatening.
•Donotuseinunventilatedareas.
•KnowthesignsofCOandCO2poisoning.
•Headaches,stingingeyes
•Dizziness,disorientation
•Difficultybreathing,feelsofbeingsuffocated
•Properventilationairexchange(OSHA29CFR1926.57)tosupportcombustionandmaintainacceptableairqualityshall
beprovidedinaccordancewithOSHA29CFRPart1926.154,ANSIA10.10SafetyRequirementsforTemporaryandPor-
tableSpaceHeatingDevicesandEquipmentusedintheConstructionIndustryortheNaturalGasandPropaneInstalla-
tionCodesCSAB149.1.
•PeriodicallymonitorlevelsofCO,CO2andNO2existingattheconstructionsite–attheminimumatthestartof
theshiftandafter4hours.
•Provideventilationairexchange,eithernaturalormechanical,asrequiredtomaintainacceptableindoorairquality.
USA8-HrTimeweightedaverage
(OSHA29CFR1926.55AppA)
Canada8-hrtimeweightedaverage
WorkSafeBCOHSGuidelinesPart5.1
andOntarioWorkplacesReg833
CO 50ppm 25ppm
CO
2
5000ppm 5000ppm
NO
2
3ppm(Reg833)
USA–CeilingLimit
(ShortTermExposureLimit=15minutes)
CanadaSTEL(15minutesReg833/1hour
WSBC)WorkSafeBCOHSGuidelinesPart
5.1andOntarioWorkplacesReg833
CO 100ppm
CO
2
15000ppm(WSBC)
30000ppm(Reg833)
NO
2
5ppm
1.0ppm(WorkSafeBC)
5.0ppm(Reg833)
•Ensurethattheflowofcombustionandventilationairexchangecannotbecomeobstructed.
•Asthebuilding‘tightensup’duringtheconstructionphasesventilationmayneedtobeincreased.
Installationofthisapplianceataltitudesabove2000ft(610m)shallbeinaccordancewithlocalcodes,orintheabsenceof
localcodes,theNationalFuelGasCode,ANSIZ223.1/NFPA54,orNationalStandardofCanada,NaturalGasandPropane
InstallationCode,CSAB149.1
Theheaterhasbeenshippedfromthefactorysetupforoperationonpropanegas.