User's Manual

Chapter 4
PC-IP Operation
55
Leakage Limit - Select Set Llimit and use the arrow keys to
increment the display to the desired limit to trigger the leakage
alarm.
Distance - Select set and use the arrow keys to select the desired
distance for the measurement (the range of values is 10 to 500
feet).
Compensation - Select Compensation and use the arrow keys to
select the desired compensation value (+ or – 6.0 dB in 1 dB
increments).
Signal Type - Select the type of signal being monitored and the
type of tagging. Use the arrow keys to select CW or Analog
moduaion with No, AM or FM Tagging.
Tag Frequency - This future enhancement will allow the user to
select a TAG FREQUENCY and use the arrow keys to increment
or the alphanumeric keys to enter the desired tag frequency from
5 to 2000 Hz.
Review the settings and click on the Database Save button to
save the setup selections
Leakage Measurements
Leakage measurements will include the channel number,
frequency, leakage measurement, peak-hold level measurement,
distance of the measurement and any compensation factor
included in the measurement. Leakage screens may be saved
viewed on the unit and up-Loaded and saved or viewed using the
PC-IP software.