MAXEONSOLARTECHNOLOGIES,LTD.
SafetyandInstallationInstructions‐Document00115497Rev.X
©June2022MaxeonSolarTechnologies,Ltd.Allrightsreserved.Specificationsincludedinthismanualaresubjecttochangewithoutnotice.
5) Maxeon specified or Maxeonsupplied mounting systems.
Modules mounted with strict adherence to Maxeon
documentation, using hardware systems supplied by or
specifiedbyMaxeon.
Figure2andTable1.1belowdemonstratethemountinglocationsand
Tables1.2and1.3giveallowedloadratings(designedtestvalue)for
Maxeonmodules.
Figure2:MountingZonelocationsforMaxeonmodules
ForPSeries,MAX396,104,112cellsandMAX666cells:

For128cells,PSeriesandMAX5/MAX6Commercial:
Table1.1:Approvedmoduleclamping/directfixationzones
ModuleConfiguration
Mountingzonedistancefrom
cornerin(mm)
1
Frame
holes
E
Modulesize
Frame
type
A B C
(1&2&3&4)
(1&2&3&4)
(1&2&3&4)
(1&2&3&4)
96cells,104
cells(MAX2,
MAX3),112
cells,P3BLK
andP3RES+
G3
(Black)
Silver&
G4.1&
G4.2&
G4.3
50350
150380
50150
Asper
Drawingin
theTable2
128cellsand
P19COM
G4&
G4.1&
G4.2
50350 408880 50375
P3COM
G4.2&
G4.3
50350 408833 50375
MAX6(66cells) G5.2 50350 265514 50265
MAX5and
MAX6COM
(72cells)
G4.2&
G5.6
50350 296536 50296
D‐Thereisa20mmzoneat388408mmfromthecornerwheremountingisnot
allowedduetothemodulestackingpinfeature.Applicableto128and96cell
commercialonly.
1) Nopartofthemoduleclampmayextendbeyondthisarea.
Figure3:MountingConfigurations
Configurations1and2showmountingwithrailsupport,3and4
showmountingwithoutrailsupport.In“WithRailSupport”therails
becomesconventionalorrailstransversewhile“WithoutRail
Support”becomesendmountedinlongorshortside.Inthecase
whentheglassdeflectsitwouldnotdeflectintherailsforadditional
support.
Table1.2:MountingZoneDesignLoadRatingsforRackingsystem
withoutrailsupportunderneaththemodule.Refertoconfiguration
3and4inFig.3
Module
Configuration
Wind(up&down)/Snow(down)
(unitsinPa)(***)
Module
size
Frame
type
End
Mount
A
(1&2&3&4)
Frame
Holes
E
(1&2&3&4)
B
(1&2&3&4)
C
(1&2&3&4)
orB+C
(B
1&3
+C
2&4
or
B
2&4
+C
1&3
)
OrA+B
(A
1&3
+B
2&4
or
A
2&4
+B
1&3
)
OrA+C
(A
1&3
+C
2&4
or
A
2&4
+C
1&3
)
96cells,
andP3BLK
G3
Black&
Silver&
G4.1&
G4.2&
G4.3
2400/
2400
(*)
2400/
5400
2400/
5400
2400/2400
104cells
(MAX2,
MAX3)and
112cells
(MAX3)
G4.2
1800/
1800
P3RES+ G4.3
1300/
1600
1600/
2400
1600/
2400
1300/
1600
128cells,
P19COM
G4&
G4.1&
G4.2
Not
applicable
(**)
2400/
5400
3600/
3600
2400/2400
P3COM
G4.2&
G4.3
1600/
1600
1600/
2400
1600/
2400
1600/1600
MAX6(66
cells)
G5.2
1600/
1600
3600/
3600
3600/
3600
1600/1600
MAX5
COM
(72cells)
G4.2
1600/
1600
3600/
3600
3600/
3600
1600/1600
MAX6
COM
(72cells)
G5.6
1067/
1200
(*):5400Paisallowedwithclampsandmountingrailsalongthelongersideoftheframe
(**):2400/2400Paareallowedwithclampsandmountingrailsalongthelongersideof
theframe
ForRooftopapplication1200/1200Paisallowedwithonlyclamps
(***)Safetyfactorof1.5included