Instruction Manual

MAXEONSOLARTECHNOLOGIES,LTD.
SafetyandInstallationInstructions‐Document00115497Rev.X
©June2022MaxeonSolarTechnologies,Ltd.Allrightsreserved.Specificationsincludedinthismanualaresubjecttochangewithoutnotice.
Platform Modulemountingandgroundholedetail FrameProfile
FORP3UPPGEN4.3(Customized)
Commercial
Modules
SIDEFRAMEPROFILE
ENDFRAMEPROFILE
FORP5UPP&P6BIFACIALGEN4.3
Commercial
Modules
SIDEFRAMEPROFILE
ENDFRAMEPROFILE
FORMAX5GEN4.2MODULES
Commercial
Modules

SIDEFRAMEPROFILE
ENDFRAMEPROFILE
2066 mm
MODEL: SPR-P19-410-COM
Rated Power (Pmax)
1
(+5/
0
%) 410
W
Voltage (Vmp) 43.9
V
Current (Imp) 9.35
A
Open-Circuit Voltage (Voc) 53.1
V
Short-Circuit Current (Isc) 9.94
A
Maximum Series Fuse 15
A
1
Standard Test Conditions: 1000 W/m
2
, AM 1.5, 25° C
Suitable for ungrounded, positive, or negative grounded DC systems
Field Wiring: Cu wiring only, min. 12 AWG/4 mm
2
, insulated for 90° C min.
WARNING
SEVERE ELECTRICAL HAZARD
• Solar module has full voltage even in very low light.
• Installation should only be done by a qualified technician.
527040
www.sunpower.com
Patented as shown at www.sunpower.com/patents
Safety Class II
Fire Rating: Class C
Max. System Voltage:1500 V DC
274 mm
1160 mm
4X Ø4.2 mm
Ground Holes
8X (14mmx9mm)
Mounting Holes
1118 mm
2022 mm
35 mm
35 mm
35 mm
35 mm
1092 mm
1043 mm
400 mm
1100 mm
1400 mm
2384 mm
4X Ø4.2mm
Ground Holes
8X 14mm (L) x 9mm (W)
R4.5mm
SLOTS
4X 10mm (L) x 7mm (W)
R3.5mm
Mounting Holes
35 mm
35 mm
35 mm
35 mm
16 mm
1935 mm
1423 mm
1200 mm
539 mm
400 mm
973 mm
980 mm
1058 mm
1999 mm
1016 mm
20x Ø6.8
Mounting Holes
4x Ø4.22
Ground Holes
4x 5mm(W) x 15mm (L)
SLOTS
32 mm
40 mm
24 mm
40 mm
MeasurementTolerancesare+/3mmfortheLengthandWidthoftheModule.