User manual
MODEL NO.: SPS-060PT SER. REV.:1.2 UL/cUL/TUV APPROVED RS020400
3/3 2003/01/07
* TOTAL OUTPUT MAXIMUM 60 WATTS.
** THE OUTPUT VOLTAGE LOAD REGULATION IS LESS THAN THE VALUES IN THE ABOVE
TABLE BY CHANGING EACH OUTPUT LOAD ±40% FROM 60% RATED OF LOAD, AND
KEEP THE OTHER OUTPUTS AT 60% OF RATED LOAD.
3. ELECTRONIC CHARACTERISTICS:
3-1. RISE TIME:
20mS MAX.
3-2. HOLD UP TIME:
16.7mS MIN, TEST CONDITION AT 115V/60Hz AC INPUT, AC OFF POINT AT 0 DEGREE.
80mS MIN, TEST CONDITION AT 230V/50Hz AC INPUT, AC OFF POINT AT 0 DEGREE.
3-3. SETUP TIME:
3Sec MAX. TEST CONDITION AT 115V AC INPUT.
1Sec MAX. TEST CONDITION AT 230V AC INPUT.
3-4. OVER LOAD PROTECTION:
WHEN OUTPUT POWER OVER 105% TO 180% OF RATED LOAD, THE POWER SUPPLY
WILL SHUTDOWN AND AUTO RECOVERY WHEN FAULT CONDITION HAS BEEN
REMOVED.
3-5. SHORT CIRCUIT PROTECTION:
WHEN OUTPUT SHORT TO GROUND, THE POWER SUPPLY WILL SHUTDOWN AND
AUTO RECOVERY WHEN SHORT CIRCUIT CONDITION HAS BEEN REMOVED.
4. MECHANICAL DATA:
OUTLINE DIMENSION : W 95 ×D 159 ×H 38 mm
5.COOLING:
NATURAL COOLING.
6. SAFETY:
THIS PRODUCT IS DESIGN TO COMPLY WITH THE FOLLOWING STANDARDS:
6-1. UL 1950 3rd EDITION (1998) APPROVED. (E 129733)
6-2. CSA C22.2 NO.950-95 3rd EDITION (1998) APPROVED BY UL.
6-3. TUV EN 60950: 1992+A1+A2+A3+A4+A11 (1997) APPROVED. (R 3-50003815)
6-4. IEC 60950:1991+A1+A2+A3+A4 (1996) APPROVED.
6-5. EMKO-TSE (74-SEC) 207/94 APPROVED.