User manual
SPS-035 / SPS-050 / SPS-060 (12V,15V,24V) 
SDS-030 
 User’s Menu 
Please read this user's guide carefully before setup. 
Input: 
1. Input range: 
SPS-035 / SPS-050 / SPS-060: 
Universal full range AC 85V ~ 264V or DC 120V ~ 375V 
SDS-030A: 9.5 ~ 18VDC / SDS-030B: 18 ~ 36VDC / SDS-030C: 36 ~ 72VDC 
2. Inrush current: When turn on input power source, there is peak current (inrush 
current) running through filter capacitor of power supply. During power supply 
operating, it is important not to turn off input power source and then immediately 
turn on it again, otherwise, it may shorten power supply’s life. 
Inrush current could be several to tens times of the normal current. It is important 
to make sure input wiring, fuse and SW are able to carry inrush current. 
3. For input specification, please refer to the label on the product or visit 
www.sunpower.com.tw
 for newly update data. 
Output: 
1. The output voltage adjustable range is  ±10% of rated output voltage. As output 
power is V
0 
x A
0
, when adjusting V
0 
to a higher value, should decrease A
0 
as well, 
ex.: 
For SPS-035-05, the rated output voltage is 5V, max output current is 7A: If 
adjusting output voltage to 5.5V, should decrease max output current to 6.3A as 
well; and even if adjusting output voltage to 4.5V, max output should not be over 
7A. 
2. For output specification, please refer to the label on the product or visit 
www.sunpower.com.tw
 for newly update data. 
Protection: 
1. Short circuit protection: When circuit shorted, power supply will shutdown. After 
short circuit has been removed, power supply will recover automatically. 
2. Over load protection: When over loaded, power supply will shutdown. After load 
reduced to meet rated range, power supply will recover automatically.   
3. Over voltage protection: When output voltage exceeds rated range, power will 
shut down. After voltage reduced to meet rated range, it will recover automatically. 
4. Input polarity reverse protection: SDS-030 series only. 
To Parallel Switching Power Supplies 
Adjusting output voltage of each power supply to a same level, and then serialize a 
diode after the positive pole of each power supply. The diode must be able to carry 
current that higher than power supply’s max output, and should be equipped with a 
proper heat sink. (It is suggested to choose a power supply which max output 
could meet your system’s requirement instead of paralleling lower output power 
supplies) 
2
LOAD
To Serialize Switching Power Supplies: 
a.  To up rise output voltage: 
INPUT
Power Supply 
(1)
INPUT
Power Supply 
(2)
12V
12V
LOAD
b.  To generate both positive and negative output voltage. 
Power Supply 
(1)
Power Supply 
(2)
12V
12V
LOAD
LOAD
INPUT
INPUT
Wiring: 
1. Output wiring must be thick and short enough to carry loading. The shorter and 
thicker the wire, the less voltage it drops (less wire loss). 
V+
Wire loss
V-
Load
2. Connecting the PE of power supply to system’s chassis with a short & thick wire 
can reduce noise and prevent electric shock. 
3. Reference data for wires:
Max. Load Current (A) 
AWG
NO.
Area
(mm
2
)
Constitution 
(Wire/mm) 
Vol. Drop/1A 
mV/m 
U1007 
(300V 80℃)
U1015 
(600V 105℃)
30 0.051 7/0.102  358  0.12  --- 
28 0.081 7/0.127  222  0.15  0.2 
26 0.129 7/0.16  140  0.35  0.5 
24 0.205 11/0.16 88.9 0.7 1.0 
22 0.326 17/0.16  57.5 1.4 2.0 
20 0.517 26/0.16  37.6 2.8 4.0 
18 0.823 43/0.16  22.8 4.2 6.0 
16 1.309 54/0.18  14.9 5.6 8.0 
14 2.081 41/0.26  9.5  ---  12.0 
12 3.309 65/0.26  6.0  ---  22.0 
10 5.262 104/0.26 3.8  ---  35.0 
Mounting: 
1. Each power supply is enclosed with mounting screws. It is suggested to use 
enclosed screws to setup power supply, otherwise, make sure its length must not 
be too long (refer to the following drawing) to cause short circuit. 
2. The input wiring should be separated from output wiring to avoid noise interfere. 
3. When multiple power supplies work together, be sure to keep proper distance 
between power supply & power supply as well as power supply and the 
environment for good air convection. Use extra cooling fans if needed. 