Copy Right Sunpower Technology Corp. 2009, All Rights Reserved.                                                                                                                   SPS-035-Dx     Rev 1.8 
Specifications subject to change without notice.                                                                                                                                                       RS-090275     FEB-27-2020 
QR0405-1 Rev,:1.0 
Features: 
*  Power ON with LED indicator 
*  Built in EMI filter, low ripple noise 
*  Over voltage protection:Shutdown and latch off 
*  Over load  &  short circuit protection:Hiccup mode 
*  100% full load burn-in test 
*  -20℃~70℃ Operating temperature 
*  UL, cUL, TUV, CB, CE approved 
*  3 years warranty 
Specification: 
INPUT 
Voltage 
88V ~ 264VAC universal full range or 125V ~ 375VDC. 
Frequency 
47 ----- 63 Hz 
Current 
<1.0A@100V AC input, full load condition 
Inrush Current (TYP.) 
30A@115V , 50A@230V AC input, Cold start at 25℃ ambient 
Leakage Current 
<1.0mA@264V AC input 
OUTPUT 
MODEL No. 
SPS-035-D1 
SPS-035-D2 
SPS-035-D8 
SPS-035-D9 
Output 
V1 
V2 
V1 
V2 
V1 
V2 
V1 
V2 
Voltage                         
5V 
12V 
5V 
24V 
12V 
-12V 
15V 
-15V 
Min Load 
0.3A 
0A 
0.3A 
0A 
0.3A 
0A 
0.3A 
0A 
Max Load 
4A 
2.5A 
4A 
1.3A 
3A 
1.5A 
2.4A 
1.5A 
Output Tolerance  
± 2% 
± 5% 
± 2% 
± 5% 
± 1% 
± 5% 
± 1% 
± 5% 
Ripple Noise MAX.  
70mV 
120mV 
70mV 
240mV 
120mV 
120mV 
150mV 
150mV 
Efficiency (TYP.)   
79% 
79% 
83% 
84% 
Output MAX. 
35W 
35W 
36W 
36W 
PROTECTION 
Over Voltage   
5.8~7.0V 
---- 
5.8~7.0V 
---- 
13.8~16.8V 
---- 
17.3~21.0V 
---- 
Shutdown and latch off, recover after re-start up. 
Over Load & Short Circuit 
When power supply over 105%~ 150% max load or short circuit acted, power supply will go into hiccup mode 
and recover automatically after the fault is removed. 
ELEC. CHAR. 
Rise time 
<30mS 
Hold up time 
>60mS@230V, full load condition   
Setup time 
<1 Sec@100  ~  240V AC 
ENVIRONMENT 
Temperature               
Operating: -20 ~ +70℃ ; De-rating: 50 ~ 70℃: 2.5%/℃ ; Storage: -40 ~ +85℃ 
Humidity 
Operating: 20% ~ 90% RH (non condensing) ; Storage: 10% ~ 95% RH (non condensing) 
Altitude 
6562 ft (  ≒  2000 m) operating  
SAFETY 
Withstand voltage 
I/P-O/P:3KVAC, I/P-FG:1.8KVAC, O/P-FG:0.5KVAC, 1minute 
Isolation resistance 
I/P-O/P, I/P-FG, O/P-FG  >100MΩ/500VDC at 25℃/ 70% RH 
Safety standard 
UL 62368-1 2
nd 
Edition, 2014-12-01, CAN/CSA C22.2 No. 62368-1-14, 2
nd
 Edition, 2014-12, TUV EN 62368-1:2014+A11, 
IEC 62368-1:2014 approved 
EMC 
EMI 
EN 55032 CLASS B, FCC CFR 47 PART 15 CLASS B 
Compliance to EN61000-3-2 CLASS A, EN61000-3-3 
EMS 
EN 55024:EN 61000-4-2,3,4,5,6,8,11 
OTHERS 
Cooling 
Natural cooling. 
M.T.B.F. 
339 K hours 
Terminal pitch 
6P / 8.25mm with plastic cover, 90 deg terminal optional (with MOQ) 
Packing   
N.W.: 0.35Kg / pc ; 46 pcs / 1.22 CUFT/ 1 CTN 
NOTE 
 All measurements which not mentioned are based on 230VAC input, output Max at ambient 25℃ / 70%RH   
 Output tolerance included set up voltage, line regulation and load regulation. 
 The regulation is measured between 20%-100% max load of each output, Total output t must under output Max. 
 Ripple & noise are measured at 100〜254VAC input with 10〜50℃ condition and 20MHz of bandwidth by using a 10〞〜15〞twisted pair-wire terminated   
with a 0.1uF & a 47uF parallel capacitor. 
 The operating temperature shall follow the de-rating curve in spec   
The output load may be requested for decreasing as de-rating curve in spec when low input voltage is under 100VAC. 
 The power supply is considered a component of end-equipment. The end-equipment must be re-confirmed whether comply with EMC directives. 
35W, Dual Output     
99 x 82 x 35 mm 
3.90  x  3.23  x  1.38  inch 
 CB   