- Sunpentown Intl. Inc. Telephone User Manual

SP-2
5. CH70 WATCH RECEIVER
(1) Receiving Frequency 156.525 MHz
(2) Sensitivity Symbol error rate: Less than 1% (at 0 dBμV)
(3) Conducted Spurious Emission Less than 2 nW
6. POWER REQUIREMENTS
(1) Power Supply 24 VDC (-10%/+30%)
(2) Power Consumption
7. DIGITAL INTERFACE IEC 61162-1 (NMEA0183 Ver.3)
Input sentence & priority
Date: ZDA > RMC
Time: ZDA > GGA > RMC > GNS > GLL
Position: GGA > RMC > GNS > GLL
Output sentence: TLL
Talker: GP>LC>DE>II>IN>EC
8. AMBIENT CONDITIONS
(1) Temperature -15°C to 55°C (IEC60945)
(2) Relative Humidity 93% (at 40°C)
(3) Waterproofing (IEC 60529)
Transceiver Unit Chassis: IPX0, Panel: IPX4
Handset/Hanger HS-2003: IPX4
Remote Station/Handset RB-8800: IPX0
HS-8800:IPX2
RB-8810: IPX0
RB-8810-W: IP
56
HS-8800-W: IP
56
Junction Box IF-8810: IPX0
DMC Interface IF-8820: IPX0
9. COATING COLOR
(1) Transceiver Unit Chassis: Munsell 2.5GY5/1.5, Panel: Munsell N3.0
(2) VHF console 7.5BG7/2, 2.5G7/2 or user spesified
Waiting
0.5 A
Receive
1.6 A at 4 W audio output
FM-8800S
Transmit
1.6 A at 1 W output,
4.7 A at 25 W output
Waiting
0.5 A
Receive
1.6 A at 4 W audio output
Transmit
2 A at 1 W output,
6 A at 25 W output
FM-8800D
DUP Transmit
3.6 A at 1 W output,
7.6 A at 25 W output