3. Pressandreleasethelearnbuttonontheheatercontrol.Pressthe<ON>buttononthewireless
devicewithin10seconds.Makesuretheremote’sredindicatorlightwentonwhilepressingthe
remote.
4. Theheatershouldnowrecognizethewirelessdevice.
a. Pressthe<OFF>buttononthe
wirelessdevice
b. Pressthe<ON>button
c. Pressthe<HI>button
d. LeaveheateronHIforfirst5minutes
Iftheheaterdoesnotlight,repeatprocedure4..Itislikelythatthereisstillairinthegasline.Ifthe
heaterfailstolightorfails
tostaylitafterseveraltries,itmaybenecessarytopurgetheairfromthegas
lineusingsafepractices.
Sunpak Pilot
The two electrodes near the pilot provide for
flame ignition and sensing. It is important that
these electrodes be position properly.
• Electrodes should be located 3/16”from the
pilot hood and within the flame zone.
• Electrodes must be spaced at least 3/8”
from each other to avoid spark from
grounding to the sensing electrode.
• The ‘L’ shaped electrode should always be
used for sensing