Datasheet

SUNONWEALTH
Page 4 of 14
3. PERFORMANCE CHARACTERISTIC
RATED SPEED 3900 RPM ± 10% at rated voltage
AIR FLOW 65.0 CFM
STATIC PRESSURE 0.25 Inch-H
2
O
ACOUSTIC NOISE 43.0 dB(A)
AIR FLOW V.S. PRESSURE See Page 5
INSULATION CLASS UL Class A
INSULATION RESISTANCE
PLASTIC HOUSING
(1)
10M ohm at 500 VDC between internal stator and
(2)
lead wire (+)
DIELECTRIC STRENGTH
Applied AC 500 V for one minute or AC 600 V for 2
Seconds between housing and lead wire (+)
LIFE EXPECTANCY
70,000 Hours at 40 deg. C, 65% humidity, 90% CL .
PROTECTION
Automatic Restart
Note: In a situation where the fan is locked by an external
force while the electricity is on, an increase in coil temperature
will be prevented by temporarily turning off the electrical
power to the motor. The fan will automatically restart when
the locked rotor condition is released.
Polarity Protection
IP Class : IP68
According to IEC 529 (or IEC 34-5) IP standard, the average
temperature is 23~24°C and humidity is 67% RH for Dust
Water Test. The fan needs to be test and Spray Put in dust box
for 8 hours for Dust Test and be put in long period immersion
of water for Spray Water Test. After these 2 tests, which
executing by regular standard, the fan will be measured the
performance is normal or not.
PS.There are different applicative environments and systems by
different customers, so please put the product in the most
suitable environment to measure the performances.
4. SAFETY
SAFETY UL CUR TUV CE
NO. E77551 E77551
2018.02.27
D.C.C.