Datasheet
建
建建
建
準
準準
準
電
電電
電
機
機機
機
SUNONWEALTH
Page 4 of 14
3. PERFORMANCE CHARACTERISTIC
RATED SPEED 3100 RPM ± 10% at rated voltage
AIR FLOW
138 CFM
STATIC PRESSURE
0.36 Inch-H
2
O
ACOUSTIC NOISE
48 dB(A)
AIR FLOW V.S. PRESSURE See Page 5
INSULATION CLASS UL Class A
INSULATION RESISTANCE
PLASTIC HOUSING
10M ohm at 500 VDC between internal stator and
lead wire (+)
DIELECTRIC STRENGTH
Applied AC 500 V for one minute or AC 600 V for 2
Seconds between housing and lead wire (+)
LIFE EXPECTANCY
70,000 Hours at 40 deg. c , 65% humidity , 90%CL.
Automatic Restart
Note: In a situation where the fan is locked by an external
force while the electricity is on, an increase in coil
temperature will be prevented by temporarily turning off the
electrical power to the motor. The fan will automatically
restart when the locked rotor condition is released.
PROTECTION
Polarity Protection
According to IEC 529 (or IEC 34-5) IP standard, the average
temperature is 23~24°C and humidity is 67% RH for Dust
Water Test. The fan needs to be test and Spray Put in dust box
for 8 hours for Dust Test and be sprayed 10 minutes with water
of 4 aspects for Spray Water Test. After these 2 tests, which
executing by regular standard, the fan will be measured the
performance is normal or not.
IP Class : IP55
PS. There are different applicative environments and systems
by different customers, so please put the product in the
most suitable environment to measure the performances.
4. SAFETY
SAFETY UL CUR TUV
NO.
E77551 E77551
2011.06.01