Data Sheet
建 準 電 機 
SUNONWEALTH 
Page 9 of 14 
 IV. CHARACTERISTIC DEFINITION 
The following is a general description of certain tests that are performed on 
representative SUNON fans in order to determine the specifications of the fan. Nothing 
in this document is intended to suggest that these tests are performed on every model of 
SUNON fan. Moreover, the descriptions that follow each test are meant only to provide 
a general explanation of each test. If you would like a more detailed explanation as to 
any test identified in this Section, SUNON can provide such an explanation upon 
request.  
1. ACOUSTICAL NOISE 
Measured in a semi-anechoic chamber with background noise level below 15dB(A). 
 1 METER FROM MICROPHONE TO FAN INTAKE 
The fan is running in free air under shaft horizontal condition with the microphone at 
distance of one meter from the fan intake. 
2. INPUT POWER 
Measured after continuous 10 minute operation at rated voltage in clean air 
( STATIC PRESSURE=0), and at ambient temperature of 25 degrees C under shaft 
horizontal condition. 
3. RATED CURRENT  
Measured after continuous 10 minute operation at rated voltage in clean air 
( STATIC PRESSURE=0), and at ambient temperature of 25 degrees C under shaft 
horizontal condition. 
2017.09.12
D.C.C.