Instructions / Assembly
Page 12 / 15PH02 08/2021
TO START THE HEATER
1. Turn on the valve on the gas supply cylinder.
2. Press and turn the variable control knob to the 'Hl' position.
3. Press down the variable control knob and hold for 30 seconds.
4. While holding down on the variable control knob, press the igniter
button until the burner head ame ignites. Release the variable control
knob 10 seconds after the ignition.
5. If a new tank has just been connected, it may take one minute or
more for the air in the gas pipeline to purge out.
6. The ame can be watched and checked from the viewing hole located
on the base of the burner.
7. Turn the variable control knob to the 'LO' position for 5 minutes or
more before turning the knob to the desired temperature setting. If
a small ame is needed, keep the variable control knob in the 'LO'
position.
8. If the burner ame goes out accidentally or it is blown out by the wind,
turn o the heater and wait at least 5 minutes or more to let the gas
dissipate before lighting again to avoid possible gas explosion─repeat
steps 2 through 4.
TO STOP THE HEATER
1. Turn the variable control knob clockwise to the 'OFF' position.
2. Tightly close the propane supply valve on the propane tank.
NOTICE
─ this is
BTU's per/hour 47,000
Gas Consumption per/hour 1.77 lbs
Injector Size 0.0778 in.
Setting Pressure 11.0 in. per W.C.
Regulator Outlet Pressure 11.0 in. per W.C.
Gas Supply Pressure 150 PSI maximum, 5 PSI minimum
Standard ANSI Z83.26-2014 Gas Fired Outdoor Infrared Patio Heaters
Specicaons
WARNING:
WARNING:
operation, immediately turn the
gas clear for at least 5 minutes
before attempting to re-light