SDS
Page 4/10
Safety Data Sheet
Regulation (EC) No. 1907/2006 and 1272/2008
Printing date 09.01.2018 Revision: 08.01.2018Version number 1
Trade name: NI-MH RECHARGEABLE BATTERY
(Contd. of page 3)
46.0.9
·
5.3 Advice for firefighters
·
Protective equipment:
No special measures required.
SECTION 6: Accidental release measures
·
6.1 Personal precautions, protective equipment and emergency procedures:
Wear protective equipment. Keep unprotected persons away.
·
6.2 Environmental precautions:
Inform respective authorities in case of seepage into water course or sewage system.
Do not allow to enter sewers/ surface or ground water.
·
6.3 Methods and material for containment and cleaning up:
Use neutralising agent.
Dispose contaminated material as waste according to section 13.
Ensure adequate ventilation.
·
6.4 Reference to other sections:
See Section 7 for information on safe handling.
See Section 8 for information on personal protection equipment.
See Section 13 for disposal information.
SECTION 7: Handling and storage
·
7.1 Precautions for safe handling:
Thorough dedusting.
Ensure good ventilation/exhaustion at the workplace.
For the general occupational hygienic measures refer to Section 8.
·
Information about fire - and explosion protection:
No special measures required.
·
7.2 Conditions for safe storage, including any incompatibilities
·
Requirements to be met by storerooms and receptacles:
No special requirements.
·
Information about storage in one common storage facility:
Not required.
·
Further information about storage conditions:
Keep container tightly sealed.
·
7.3 Specific end use(s):
No further relevant information available.
SECTION 8: Exposure controls/personal protection
·
8.1 Control parameters
·
Ingredients with limit values that require monitoring at the workplace:
1310-58-3 potassium hydroxide (31.6%)
WEL (Great Britain) Short-term value: 2 mg/m³
VME (France) Short-term value: 2 mg/m³
12054-48-7 nickel dihydroxide (20.0%)
WEL (Great Britain) Long-term value: 0.5 mg/m³
as Ni; Sk; Carc
MAK (Germany) einatembare Fraktion; vgl.Abschn.XII
VME (France) Long-term value: 1 mg/m³
C1A, M2, R1B
1345-25-1 iron oxide (16.7%)
AGW (Germany) Long-term value: 1.25* 10** mg/m³
2(II);*alveolengängig**einatembar; AGS, DFG
(Contd. on page 5)
EU