Installation Guide
8 of 11 
OFF
HIGH
MAX
BAS
ARRET
LOW
OPERATION 
LEAK TEST 
1-  Make sure the control knob is on the “OFF” position. 
2-  Make sure the gas cylinder is correctly and securely connected to the pressure regulator, without 
over tightening it. 
3-  Turn  on  the  gas  cylinder  valve.  Apply  50%  soap  and  50%  water  solution  to  the  gas  hose  and 
connections between the control knob and gas cylinder.   
4-  If something is leaking, you will see bubbles form. In case of leaks, turn off the gas supply, undo the 
leaking connection, re-connect it and try again. If the leak persists, consult Customer Service Center for 
assistance. 
5-  If the connection is sound, continue to the next step. 
IGNITE LIGHTING 
1-  Make sure control valve is OFF. 
2-  Turn on gas tank valve. 
3-  Press in and turn control valve knob counterclockwise 
  to High to ignite. See the figure to the right. 
4-  If burner is lit, do not stop pressing in the control valve knob for 
  a minute to heat the thermocouple. 
5- When  control  valve  knob  is  released,  the  burner  should be  lit.  If  not,  turn control  valve  knob 
clockwise to OFF. Wait 5 minutes after completing Step 3 before attempting to re-ignite. 
6-  Press in and turn control valve knob to desired heat input, HIGH ~ LOW. 
!!!WARNING!!! 
  Do not use an open flame to check for leaks. 
  Do not smoke during testing. 
  Do not test indoors. 
  A leak check must be performed whenever the gas cylinder is replaced. 
Fig 6