Safety Information
Issue Date:
Page 5 of 36
Report Reference #
E314798-A5-UL
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
2
PROTECTION FROM HAZARDS
Pass
2.1
Protection from electric shock and energy hazards
N/A
2.1.1
Protection in operator access areas
To be evaluated in the end
product.
N/A
2.1.1.1
Access to energized parts
Class III unit intended to be
powered by a SELV circuit in
the end-product.
N/A
Test by inspection .................................... :
N/A
Test with test finger (Figure 2A) ............... :
N/A
Test with test pin (Figure 2B) ................... :
N/A
Test with test probe (Figure 2C) ............... :
No TNV circuit.
N/A
2.1.1.2
Battery compartments
N/A
2.1.1.3
Access to ELV wiring
N/A
Working voltage (Vpeak or Vrms);
minimum distance through insulation (mm)
................................................................. :
-
2.1.1.4
Access to hazardous voltage circuit wiring
N/A
2.1.1.5
Energy hazards ........................................ :
Unit is intended for building-in.
Accessiblity to hazardous
energy to be evaluated in the
end product.
N/A
2.1.1.6
Manual controls
N/A
2.1.1.7
Discharge of capacitors in equipment
N/A
Measured voltage (V); time-constant (s) .. :
-
2.1.1.8
Energy hazards - d.c. mains supply
N/A
a) Capacitor connected to the d.c. mains
supply ....................................................... :
N/A
b) Internal battery connected to the mains
supply ....................................................... :
N/A
2.1.1.9
Audio amplifiers ........................................ :
N/A
2.1.2
Protection in service access areas
N/A
2.1.3
Protection in restricted access locations
N/A