Safety Information
Issue Date:
Page 3 of 36
Report Reference #
E314798-A5-UL
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
1.7
Marking and instructions
Pass
1.7.1
Power rating and identification markings
Unit not provided with means
for connection to mains.
Pass
1.7.1.1
Power rating mark
N/A
Multiple mains supply connections ........... :
N/A
Rated voltage(s) or voltage range(s) (V) .. :
N/A
Symbol for nature of supply, for d.c. only . :
N/A
Rated frequency or rated frequency range
(Hz) .......................................................... :
N/A
Rated current (mA or A) ........................... :
N/A
1.7.1.2
Identification markings
Pass
Manufacturer's name or trademark or
identification mark .................................... :
Sunix Co., Ltd.or File Number
E314798
Pass
Model identification or type reference ...... :
Refer to the Model information
at the beginning of this Test
Report.
Pass
Symbol for Class II equipment only .......... :
Class III equipment.
N/A
Other markings and symbols .................... :
Additional symbols may be
provided when submitted for
National Approval.
N/A
1.7.2
Safety instructions and marking
Safety instructions in English.
Other languages will be
provided when submitted for
national approval.
Pass
1.7.2.1
General
Pass
1.7.2.2
Disconnect devices
N/A
1.7.2.3
Overcurrent protective device
N/A
1.7.2.4
IT Power distribution systems
N/A
1.7.2.5
Operator access with a tool
N/A
1.7.2.6
Ozone
N/A
1.7.3
Short duty cycles
N/A
1.7.4
Supply voltage adjustment ....................... :
N/A
Method and means of adjustment;
reference to installation instructions ......... :
N/A