Safety Information

Issue Date:
Page 22 of 36
Report Reference #
E314798-A5-UL
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
4.7
Resistance to fire
Pass
4.7.1
Reducing the risk of ignition and spread of flame
Pass
Method 1, selection and application of components
wiring and materials
Pass
Method 2, application of all of simulated fault
condition tests
N/A
4.7.2
Conditions for a fire enclosure
Unit intended for building-in.
To be investigated in the end
product.
N/A
4.7.2.1
Parts requiring a fire enclosure
Unit intended for building-in.
To be investigated in the end
product.
N/A
4.7.2.2
Parts not requiring a fire enclosure
N/A
4.7.3
Materials
Pass
4.7.3.1
General
The propagation of fire is
minimized through the fire
enclosure construction.
Pass
4.7.3.2
Materials for fire enclosures
Unit intended for building-in.
To be investigated in the end
product.
N/A
4.7.3.3
Materials for components and other parts outside
fire enclosures
Unit intended for building-in.
To be investigated in the end
product.
N/A
4.7.3.4
Materials for components and other parts inside fire
enclosures
All internal materials are rated
V-2 or better or are mounted
on a PWB rated V-1 or better.
Pass
4.7.3.5
Materials for air filter assemblies
N/A
4.7.3.6
Materials used in high-voltage components
N/A