Safety Information
Issue Date:
Page 11 of 36
Report Reference #
E314798-A5-UL
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
2.10
Clearances, creepage distances and distances through insulation
Pass
2.10.1
General
Supplied by SELV, and no
hazardous voltage generated
within unit, only functional
insulation required.
For functional insulation, see
5.3.4.
Pollution degree 2 applicable.
Pass
2.10.1.1
Frequency ................................................ :
N/A
2.10.1.2
Pollution degrees ..................................... :
Pollution degree 2
Pass
2.10.1.3
Reduced values for functional insulation
There is no minimum
CLEARANCE or CREEPAGE
DISTANCE for FUNCTIONAL
INSULATION unless it is
required by 5.3.4 a).
Pass
2.10.1.4
Intervening unconnected conductive parts
N/A
2.10.1.5
Insulation with varying dimensions
N/A
2.10.1.6
Special separation requirements
N/A
2.10.1.7
Insulation in circuits generating starting pulses
N/A
2.10.2
Determination of working voltage
N/A
2.10.2.1
General
N/A
2.10.2.2
RMS working voltage
N/A
2.10.2.3
Peak working voltage
N/A
2.10.3
Clearances
See 2.10.1.
N/A
2.10.3.1
General
N/A
2.10.3.2
Mains transient voltages
N/A
a) AC mains supply .................................. :
N/A
b) Earthed d.c. mains supplies ................. :
N/A
c) Unearthed d.c. mains supplies ............. :
N/A
d) Battery operation .................................. :
N/A
2.10.3.3
Clearances in primary circuits
N/A
2.10.3.4
Clearances in secondary circuits
See 2.10.1.
N/A