Safety Information
Issue Date:
Page 6 of 36
Report Reference #
E314798-A5-UL
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
2.2
SELV circuits
Pass
2.2.1
General requirements
Class III unit intended to be
powered by a SELV circuit in
the end-product.
Pass
2.2.2
Voltages under normal conditions (V) ...... :
All accessible voltages are
less than 42.4 Vp or 60 Vdc
and are classified as SELV.
Pass
2.2.3
Voltages under fault conditions (V) .......... :
The unit is supplied by SELV
and all critical fault conditions
were considered in power
supply evaluation.
Pass
2.2.4
Connection of SELV circuits to other
circuits ...................................................... :
SELV circuits are only
connected to other secondary
circuits
Pass
2.3
TNV circuits
N/A
2.3.1
Limits
No TNV circuit.
N/A
Type of TNV circuits ................................. :
-
2.3.2
Separation from other circuits and from accessible
parts
N/A
2.3.2.1
General requirements
N/A
2.3.2.2
Protection by basic insulation
N/A
2.3.2.3
Protection by earthing
N/A
2.3.2.4
Protection by other constructions ............. :
N/A
2.3.3
Separation from hazardous voltages
N/A
Insulation employed ................................. :
-
2.3.4
Connection of TNV circuits to other circuits
N/A
Insulation employed ................................. :
-
2.3.5
Test for operating voltages generated externally
N/A