Spec Sheet

12
Never fill the cylinder beyond 80 percent full.
Place the dust cap on the cylinder valve outlet whenever the cylinder is not in use. Only install the
type of dust cap on the cylinder valve that is provided with the cylinder valve. Other type of caps or
plugs may result in leakage of propane.
OPERATION INSTRUCTIONS
Leak Check
1. Make 2-3 oz. of leak check solution (one part liquid dishwashing detergent and three parts
water).
2. Apply several drops of solution where hose attaches to regulator.
3. Apply several drops of solution where regulator connects to cylinder.
4. Make sure all patio heater and light valves are OFF.
5. Turn cylinder valve ON.
If bubbles appear at any connection, there is a leak.
1. Turn cylinder valve OFF.
2. If leak is at hose/regulator connection: tighten connection and perform another leak test. If
bubbles continue appearing, the hose should be returned to the place of purchase.
3. If leak is at regulator/cylinder valve connection: disconnect, reconnect, and perform another
leak check. If you continue to see bubbles after several attempts, cylinder valve is defective and
should be returned to cylinder’s place of purchase.
If NO bubbles appear at any connection, the connections are secure.
NOTE: Whenever gas connections are loosened or removed, you must perform a complete leak
test.
4. Complete installation.
• Perform all leak tests outdoors.
• Extinguish all open flames.
• NEVER leak test when smoking.
• Do not use the heater until all connections have been leak tested and do not leak.
Regulator / Cylinder
Connection
Hose / Regulator
Connection