User's Manual
Table Of Contents
- 1 About this Manual
- 2 Safety Instructions
- 3 Product Introduction
- 4 Installation Flow
- 5 Unpacking and Storage
- 6 Mechanical Installation
- 7 Electrical Connection
- 7.1 Safety Instructions
- 7.2 Port Introduction
- 7.3 Overview
- 7.4 Connecting to the Inverter
- 7.5 Connecting to the Meteo Station
- 7.6 Connecting to the Energy Meter
- 7.7 Wiring of DI Signal
- 7.8 Wiring of DO Signal
- 7.9 Wiring of AI Signal
- 7.10 Wiring of PT Signal
- 7.11 Connecting to the Remote Monitoring Device
- 7.12 Connecting to the AC Power Supply
- 7.13 Connecting to the DC Power Supply
- 7.14 Earthing Connection
- 8 Commissioning
- 9 Web Interface
- 9.1 Running Requirements
- 9.2 Login Steps
- 9.3 Web Main Interface
- 9.4 Operation Procedure
- 9.5 Overview
- 9.6 Device Monitoring
- 9.7 Device Maintenance
- 9.8 History Data
- 9.9 System
- 9.9.1 Running Information
- 9.9.2 System upgrade
- 9.9.3 Log export
- 9.9.4 Rebooting
- 9.9.5 Reset all setting
- 9.9.6 Remote Maintenance
- 9.9.7 Message Export
- 9.9.8 System Time
- 9.9.9 Forwarding Configuration
- 9.9.10 IEC104
- 9.9.11 MODBUS
- 9.9.12 Third-party portal
- 9.9.13 Forward GOOSE Service Configuration
- 9.9.14 Interface
- 9.9.15 MPLC
- 9.9.16 More
- 9.9.17 About
- 10 Grid Dispatching
- 11 Maintenance
- 12 Troubleshooting
- 13 FAQ
- 14 Appendix A: Technical Data
- 15 Appendix B: Related Drawings
- 16 Appendix C: General Information
55
RReemmoottee mmaaiinntteennaannccee sswwiittcchh
ssttaattee
DDeessccrriippttiioonn
Disabled
Not allow for remote maintenance on the
Logger4000
Enable Allow for remote maintenance on the
Logger4000
In case the remote maintenance switch is in the "Enable" state, the remote service
address needs to be set.
• Users in mainland China select "Chinese Server",
• Users in Europe select "European Server".
• Users in Australia select "Australian Server";
• Users in other regions select the "International Server".
9.9.7 Message Export
step 1 Click "System" -> "Message export" to enter the corresponding interface.
step 2 Set parameters, including interface, serial port, and duration, and click "Start" to start
recording message. The recording automatically stops when the set time reaches, or
the user may manually click the button "Stop" to stop recoding message.
step 3 Click "Export" to export the message.
-- -- EEnndd
9.9.8 System Time
Click the "System time" to check whether the current system time is correct,
synchronize the system time, and enable/disable "Inverter timing".
Click "System" -> "System time" to enter the corresponding interface.
User Manual 9 Web Interface