User's Manual
Table Of Contents
- 1 About this Manual
- 2 Safety Instructions
- 3 Product Introduction
- 4 Installation Flow
- 5 Unpacking and Storage
- 6 Mechanical Installation
- 7 Electrical Connection
- 7.1 Safety Instructions
- 7.2 Port Introduction
- 7.3 Overview
- 7.4 Connecting to the Inverter
- 7.5 Connecting to the Meteo Station
- 7.6 Connecting to the Energy Meter
- 7.7 Wiring of DI Signal
- 7.8 Wiring of DO Signal
- 7.9 Wiring of AI Signal
- 7.10 Wiring of PT Signal
- 7.11 Connecting to the Remote Monitoring Device
- 7.12 Connecting to the AC Power Supply
- 7.13 Connecting to the DC Power Supply
- 7.14 Earthing Connection
- 8 Commissioning
- 9 Web Interface
- 9.1 Running Requirements
- 9.2 Login Steps
- 9.3 Web Main Interface
- 9.4 Operation Procedure
- 9.5 Overview
- 9.6 Device Monitoring
- 9.7 Device Maintenance
- 9.8 History Data
- 9.9 System
- 9.9.1 Running Information
- 9.9.2 System upgrade
- 9.9.3 Log export
- 9.9.4 Rebooting
- 9.9.5 Reset all setting
- 9.9.6 Remote Maintenance
- 9.9.7 Message Export
- 9.9.8 System Time
- 9.9.9 Forwarding Configuration
- 9.9.10 IEC104
- 9.9.11 MODBUS
- 9.9.12 Third-party portal
- 9.9.13 Forward GOOSE Service Configuration
- 9.9.14 Interface
- 9.9.15 MPLC
- 9.9.16 More
- 9.9.17 About
- 10 Grid Dispatching
- 11 Maintenance
- 12 Troubleshooting
- 13 FAQ
- 14 Appendix A: Technical Data
- 15 Appendix B: Related Drawings
- 16 Appendix C: General Information
24
7.2 Port Introduction
The layout and identifiers of Logger4000 terminals are shown below.
IIddeennttiiffiieerr NNaammee
RReeccoommmmeennddee--
dd ccaabbllee
DDeessccrriippttiioonn
FE1~FE4
Ethernet port
-
Can be connected to the
background through devices
like switch and router.
SFP1, SFP2
Fiber port
-
Function reserved
ETH
Fast dispatch
port
-
Used for fast active and
reactive power control via
Goose protocol
CONSOLE
Debug port
-
Reserved
DI
Digital input
0.75mm
2
outdoor anti-
ultraviolet wire
Passive dry contact input port
USB
USB port
-
Reserved
Micro SD
SD port
-
Used for software
programming (this port is only
available to SUNGROW
technicians)
Debug Debug port
-
Used for debugging of
Logger4000
RST Reset
-
Press and hold (> 30s) to
restart Logger4000 and
restore factory settings
Short press (< 3s),
function reserved
DO1~DO4
Digital output
0.75mm
2
outdoor anti-
ultraviolet wire
Relay output interface
Relay specification: 250Vac/
1A or 30Vdc/1A
PT1, PT2,
AI1~AI4
Analog input
0.75mm
2
outdoor anti-
ultraviolet wire
PT100/PT1000 detect range:
-30℃~120℃
Two-wire or three-wire
connection method
AI1~AI2:0~10Vdc
AI3~AI4:4~20mA
7 Electrical Connection User Manual