PSA265 TECHNICAL SHEET
15 Ft. 15 Ft.
SUGGESTED SPACING WHEN
MULTIPLE HEATERS
ARE USED:
Spacing For - WELL PROTECTED AREAS
AND MILD CLIMATIC CONDITIONS
12 Ft. 12 Ft.
Spacing For - SEMI EXPOSED AREAS
WITH AVERAGE WEATHER CONDITIONS
8 Ft. 8 Ft.
Spacing For - COMPLETELY EXPOSED AREAS
WITH SEVERE WEATHER CONDITIONS
Sunglo™ Patio Heaters
( ) ( )
Model PSA265 V , E
Suggested Specifications:
Heater shall be Sunglo™ model PSA265, PSA265V, or
PSA265E as manufactured by Infrared Dynamics, Inc.,
Yorba Linda, California. All heaters shall be equipped
with a control system for use with natural gas fuel.
Each heater shall have passed the ANSI requirements
for outdoor heaters.
Reflector shall be of a deep disk circular type mounted
on top of heater.
Infrared Radiant Emitter Grid shall be made of
perforated stainless steel.
Each heater shall be equipped with a 100% safety
shutoff device.
PSA265 heaters require no electrical connection and are the
easiest to service and maintain. This heater utilizes a pilot-
thermocouple 100% safety shutoff. Pilot must be manually lit.
Heater is turned off/on with a manual control knob located at
the front of the heater.
PSA265V heaters require 24 VAC electrical to be connected
in order to operate the main burner. This heater utilizes a
pilot-thermocouple 100% safety shutoff. Pilot must be
manually lit. Heater is turned off/on with electrical switch,
timer or other control device by interrupting the 24 VAC
supply to the heater. Control device is to be supplied by the
installer. Manual control knob must be set to the ON position
for this heater to operate with an electrical switch.
PSA265E heaters require 24 VAC electrical to be connected
in order to operate. This heater utilizes an electronic ignition
and monitors the heater through flame rectification. Heater
cannot be manually lit. Heater is turned off/on with electrical
switch, timer or other control device by interrupting the 24
VAC supply to the heater. Control device is to be supplied by
the installer.
The required clearance from combustible materials must be
maintained on all heaters. In addition heaters must have
adequate fresh air and ventilation to operate properly. Make
sure you can meet these requirements in making your heater
selection.
This specification sheet was designed as a brief summary
about this heater. The primary use of this sheet should be for
heater selection only. It should not be used as the sole guide
in placement and installation of these heaters. Complete
installation instructions can be obtained by calling toll free at
1-888-317-5255 and online at www.infradyne.com.
The Original Outdoor Patio Heater
sun glosun glo
R
100% Safety Shutoff Control
Gas Inlet
½” Pipe Coupling
½” 90 Elbow
All external piping must be
protected against trip
hazards.
18”
Reflector
Radiant Emitter Grid
Pilot Lighting Hole
Heater Head Base
Slip Collar
3” Dia. Steel Post
½” Gas Pipe
12” Minimum
Approved Manual
½” Gas Shut-Off Valve
WARNING
Top Clearance
34 ½”Diameter
24” Side
Clearance
12”
7½”Ref.
84”
Ground Level
Under Ground
½”PVC
Plastic Tubing
½”Gas Inlet Pipeline
for 50,000 BTU/Hr
U/L or CSA
Certified Waterproof
Outdoor Junction Box