Fuse
A fuse is required in order to protect the wiring. A
standard automobile fuse is recommended and the
fuse should be wired to the positive (“+”) side of the
system close to the positive battery terminal. For
12V operation, use a 15A fuse, and for 24Voperation
use a 7.5A fuse.
Operating Voltage Fuse
12V 15A
24V 7.5A
ATTENTION: If a longer connection cable is necessary, the cable cross section (or gauge) must be equal to or
greater than the cable sizes recommended on the following table. Be careful that the input voltage
at the appliance does not drop below the cut-out voltage of the compressor.
Cable Size
Area AWG
mm
2
Gauge
2.5 4
412
610
10 8
12V
Cable Length
m ft.
2.5 8
413
6 19,5
10 32,8
24V
Cable Length
mft.
516
826
12 39
20 65,6
Low Voltage Disconnect
The compressor electronics includes a low voltage
disconnect feature. If the input voltage to the appli-
ance falls below 10.4V (in 12 V mode) or 22.8V (in
24 V mode), the compressor will shut-off. Once the
voltage increases above 11.7V (in 12V mode) or
24.2V (in 24V mode), the compressor will resume
normal operation.
This feature is designed to protect the system battery
from experiencing too low a depth of discharge.
12V Operation 24V Operation
Cut- in 11.7V 24.2V
Cut - out 10.4V 22.8V
OPERATION
The SunDanzer refrigerating appliance, like any battery-powered refrigerating appliance, requires care unique from
appliances plugged into an electric utility. Prudent operation is the key to extended service.
or 7.5A fuse