Page 30
OZONATOR
O
3
GRN
TB1
240 VAC, 1 PHASE, 60 Hz
USE COPPER CONDUCTORS ONLY
WIRE SIZE MUST BE APPROPRIATE
PER NEC AND/OR LOCAL CODES
RED
RED BLK
WHT
WHT
RED
BLK
BLK
WHT
BLK
RED RED
BLK BLK
BLK
21
HEATER
5.5 kW
PRESSURE SWITCH
HI - LIMIT / FREEZE SENSOR
TEMPERATURE SENSOR
J1
J2
J3
F1
30A, 250V
SC-30
PUMP 1
PUMP 2
HOT TUB
LIGHT
TRANSFORMER
240 VAC
Palermo / Bahia Panel
J4
R
Y
JP1
4
2
3
1
65
87
7624
HI
HI
LO
THERM
SWITCH
1
3
Electrical Wiring Diagram
Palermo and Bahia Domestic (60 Hz)