Instructions / Assembly
Radon Print
http://suncourt.com/Radon%20Print.html[3/8/2012 1:49:07 PM]
MOUNTING BRACKET
The fan may be further secured with the mounting brackets provided.
The flexible couplings will provide means of disconnect for cleaning the impeller and also
to isolate vibration.
ELECTRICAL WIRING
The fans operate on standard 120V 60 Hz AC. All wiring must be performed in accordance
with the National Electrical Code and state and local building codes. A qualified electrician
should perform all electrical work. Outdoor installations require the use of UL Listed
watertight conduit and power supplied from a GFCI (Ground Fault Circuit Interruptor).
ELECTRICAL CONNECTION
Connect wiring with terminal block provided, observing proper connections.