User's Manual

Table Of Contents
3.12 Range indication
3.12.1 Out of range tone
If the following conditions are applied:
The handset has been out of range since EEP_RANGE_OUT_DELAY s
If range warning tone option is ON
then a TONE_WARNING will be played.
EEP_RANGE_OUT_DELAY : selected by EEPROM data
3.12.2 In range tone
If a TONE_WARNING has been played, a TONE_IN_RANGE is played when the handset goes into
range the next time.
Note: at start-up, the handset plays the TONE_IN_RANGE only if it goes into range after more than 10
s.
3.12.3 Range limit tone during a call
During a call, in range limit conditions, the handset will play a TONE_WARNING in the Buzzer
The tone is repeated until range conditions are good
If the handset goes out of range, the call is released (on both handset and base).
3.13 Clock and Alarm clock
3.13.1 Clock
The handset has clock indication. The clock data is inside the base unit. So, all the handsets have
same clock indication.
Update the time by using one of handset.
The time data is also updated by CLIP data if the CLIP data has time data.
3.14 Alarm activation
When the unit is set to alarm ON and the clock reach to the alarm setting time, the handset shall
generate the alarm sound. And Alarm icon
needs to be turned ON on the LCD. Once the clock is
reach to alarm setting time, start to generate the alarm sound. When stop generating alarm sound, the
alarm setting shall be OFF and the icon
shall be turned OFF.
3.14.1 During idle
The sound level shall follow the handset internal ring level. However, if the setting is “OFF” the alarm
sound level shall be “Level 1”. During generating the alarm sound, press any key to stop the alarm
without any operation even the handset is “Key Lock” mode. For example, press “KEY_HOOK” to
stop the alarm, however, the handset should not go to talk mode.
If do not press any key for more than one minute, the alarm shall stop automatically.
3.14.2 During Talk
26 of 40