Natural Gas
Conversion
WARNING
This conversion kit shall be installed by a qualied service agency in accordance with the manufacturer’s
instructions and all applicable codes and requirements of the Authority Having Jurisdiction. If the information
in these instructions is not followed exactly, a re, explosion or production of carbon monoxide may result
causing property damage, personal injury or loss of life. The qualied service agency is responsible for the
proper installation of this kit. The installation is not proper and complete until the operation of the converted
appliance is checked as specied in the manufacturer’s instructions supplier with the kit.
6. Retain the rating plate for your records.
natural gas xture
natural gas supply
piping system
7
7. Perform Natural Gas Leak Test
(I) Make 2-3 oz. of leak test solution (one part liquid
dishwashing detergent and three parts water).
(II) Apply several drops of solution where natural gas
xture attaches to natural gas supply pipping system
connection. If NO bubbles appear, the connections
are secure. If bubbles appear, the connection has a
leak, disconnect, reconnect, perform another leak test.
If you continue to see bubbles after several attempts,
the part is defective and should be replaced.
6
1-877-387-3639 | Page 11
Jay Trends Merchandising Inc.
9600 Meilleur St Suite 101,
Montreal, Quebec, H2N 2E3 Canada.
Model: 9710
Serial number:
MFG Date: 12/2019
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
An LP-cylinder not connected for use shall not be stored in the vicinty of this or any other appliance.
DANGER
CARBON MONOXIDE HAZARD
This appliance can produce carton monoxide
which has no odor.
Using it in an enclosed space can kill you.
Never use this appliance in and enclosed space
such as a camper, tent, car or home.
Normal Hourly Input Rating “Input: 50,000 Btu/hr (14.65 kw)
Type of gas: Nature or Propane. This appliance is equipped for Propane.
“For Outdoor Use Only. If Stored Indoors, Detach and Leave Cylinder Outdoors.”
“The gas supply must be turned off at the propane gas supply cylinder when this appliance
is not In use.” Minimum clearance from sides & top of unit to adjacent combustible
construction is 64 inches.
CAUTION: The gas pressure regulator provided with the appliance must be used. This
regulator is set for an outlet pressure of 11 inches water column
Design complies with ANS Z21.97-2017 · CSA2.41-2017, Outdoor Decorative Gas Appliances.
Max. gas supply 6791.3 in wc (1725 kPa). Manifold pressure 11 in wc (2.74 kPa).
LIGHTING:
2.Read instructions before lighting.
3.Press and hold electronic igniter button.
4.Turn the burner control to the low position, press and hold when
the burner lights, release the electronic igniter button.
5.Continue to depress the burner control knob for 30 seconds and
then release. If the flame goes out, repeat the procedure.
6. Adjust the flame to the desired height with the burner control knob.
7.If the burner will not light with the electronic igniter, hold a lit long
match or lit long butane lighter to the ignition area of the burner and
continue with step 4.
TURNING OFF
1. Turn the burner control knob clockwise
to the off position.
2. Turn the gas off at the source (propane
cylinder valve).
WARNING: If the burner does not light within 10 seconds, turn the valve off and wait 5 minutes for gas to dissipate
before repeating the procedure.
WARNING:
Improper installation, adjustment, alteration,
service or maintenance can cause property damage, personal
Refer to the owner’s information manual provided with this
appliance. Installation and service must be performed by a
qualified installer, services agency, or the gas supplier.
injury or loss of life.
1.For Installation on Non-combustible floors only.
WARNING:
Orifice size for Nature is 3.54mm, Orifice size for Propane is 2.15mm,
Do not connect to a remote gas supply.
CAUTION: