64 Netra t 1400/1405 Installation and User’s Guide • September 1999
Controlling LOMlite
The following commands can be sent to LOMlite when it is connected:
Commands can be abbreviated to a minimum of two unique characters.
TABLE 10-1 LOMlite Commands
Command Use
alarmoff n Set alarm n off. n can be 1, 2 or 3
alarmon n Set alarm n on. n can be 1, 2 or 3
check Reset monitoring to report all failures
console Not applicable to the Netra t 1400/1405
environment Display the status of the fans, power supply, alarms and fault LED
faulton Set the Fault light to on
faultoff Set the Fault light to off
help Display the list of LOMlite commands
poweron Power the system on
poweroff Power the system off
reset Reset the system
show model Show the system model
show hostname Show the system name (equivalent to uname -n)
show eventlog Show the event log
show Show all the information available with the show command
version Show the version number of the LOMlite device