User Guide
Référence alphabétique des commandes 61
Exemple
Exemple de sortie de la commande showenvironment :
EXEMPLE DE CODE 21 Utilisation de la commande showenvironment
lom>showenvironment
Slot Device Sensor Value Units Age Status
---- --------- --------- ------ --------- ------- ------
SSC1 SBBC 0 Temp. 0 37 Degrees C 1 sec OK
SSC1 CBH 0 Temp. 0 45 Degrees C 1 sec OK
SSC1 Board 0 Temp. 0 24 Degrees C 1 sec OK
SSC1 Board 0 Temp. 1 22 Degrees C 1 sec OK
SSC1 Board 0 Temp. 2 28 Degrees C 1 sec OK
SSC1 Board 0 1.5 VDC 0 1.49 Volts DC 1 sec OK
SSC1 Board 0 3.3 VDC 0 3.35 Volts DC 1 sec OK
SSC1 Board 0 5 VDC 0 5.01 Volts DC 1 sec OK
/N0/PS0 Input 0 Volt. 0 - - 6 sec OK
/N0/PS0 48 VDC 0 Volt. 0 48.00 Volts DC 6 sec OK
/N0/PS1 Input 0 Volt. 0 - - 5 sec OK
/N0/PS1 48 VDC 0 Volt. 0 48.00 Volts DC 5 sec OK
/N0/FT0 Fan 0 Cooling 0 Auto 5 sec OK
/N0/FT0 Fan 1 Cooling 0 Auto 5 sec OK
/N0/FT0 Fan 2 Cooling 0 Auto 5 sec OK
/N0/FT0 Fan 3 Cooling 0 Auto 5 sec OK
/N0/FT0 Fan 4 Cooling 0 Auto 5 sec OK
/N0/FT0 Fan 5 Cooling 0 Auto 5 sec OK
/N0/FT0 Fan 6 Cooling 0 Auto 5 sec OK
/N0/FT0 Fan 7 Cooling 0 Auto 5 sec OK
/N0/RP0 Board 0 1.5 VDC 0 1.51 Volts DC 5 sec OK
/N0/RP0 Board 0 3.3 VDC 0 3.35 Volts DC 5 sec OK
/N0/RP0 Board 0 Temp. 0 22 Degrees C 5 sec OK
/N0/RP0 Board 0 Temp. 1 22 Degrees C 5 sec OK
/N0/RP0 SDC 0 Temp. 0 63 Degrees C 5 sec OK
/N0/RP0 AR 0 Temp. 0 47 Degrees C 5 sec OK
/N0/RP0 DX 0 Temp. 0 62 Degrees C 5 sec OK
/N0/RP0 DX 1 Temp. 0 66 Degrees C 5 sec OK
/N0/RP2 Board 0 1.5 VDC 0 1.49 Volts DC 4 sec OK
/N0/RP2 Board 0 3.3 VDC 0 3.33 Volts DC 4 sec OK
/N0/RP2 Board 0 Temp. 0 24 Degrees C 5 sec OK
/N0/RP2 Board 0 Temp. 1 23 Degrees C 5 sec OK
/N0/RP2 SDC 0 Temp. 0 57 Degrees C 5 sec OK
/N0/RP2 AR 0 Temp. 0 42 Degrees C 5 sec OK
/N0/RP2 DX 0 Temp. 0 53 Degrees C 5 sec OK
/N0/RP2 DX 1 Temp. 0 56 Degrees C 5 sec OK
/N0/SB0 Board 0 1.5 VDC 0 1.50 Volts DC 4 sec OK
/N0/SB0 Board 0 3.3 VDC 0 3.33 Volts DC 5 sec OK
commandref.book Page 61 Wednesday, March 17, 2004 10:58 AM