Operation Manual
Chapter 10 Using LOMlite 65
Configuring LOMlite
LOMlite has as an associated configuration file, lom.conf, in which you can set the
following parameters:
Each field must be on a separate line, and be followed by an equals sign (=) and a
value, without spaces. In Boolean fields, 1 means true and 0 means false.
Fault LED
LOMlite drives the amber fault LED on the system. The amber fault LED flashes
when a fan or PSU has failed. The LED is lit continuously when the watchdog has
timed out, or when the LED has been turned on manually for verification with the
LOMlite command faulton.
TABLE 10-2 LOMlite Configuration File Parameters
Field Format Use
wdog_enabled Boolean Enable the LOMlite system watchdog
when driver loads.
wdog_reset Boolean Reset the system after a watchdog
timeout.
wdog_alarm3 Boolean Turn fault LED on after a watchdog
timeout.
wdog_timeout Integer Set the timeout for the LOMlite system
watchdog. Value is in seconds.
serial_events Boolean Report LOMlite events over the serial
connection.
disable_wdog_on_break Boolean Not applicable to the Netra t 1400/
1405
disable_wdog_on_panic Boolean Try to disable the LOMlite watchdog
after a system panic. In some cases,
this can fail and the watchdog can time
out anyway.
LW3User.book Page 65 Wednesday, November 10, 1999 9:00 AM