Operation Manual
36 Netra t 1400/1405 Installation and User’s Guide • September 1999
Alarms Ports
The alarms service port connector is located on the alarms card. This connector is a
male DB-15 and
TABLE 4-7 lists each connector pin assignment.
FIGURE 4-7 DB-15 (Male) Alarms Service Port Connector
The remote Lights Out Management serial port is located below the alarms port. The
connector is a shielded RJ45 and
TABLE 4-8 lists the connector pin assignments.
TABLE 4-7 Alarms Service Port Connector Pinout
Pin Signal Name Pin Signal Name
1 Not connected 9 ALARM1_NC
2 Not connected 10 ALARM1_COM
3 Not connected 11 ALARM2_NO
4 Not connected 12 ALARM2_NC
5 ALARM3_NO 13 ALARM2_COM
6 ALARM3_NC 14 Not connected
7 ALARM3_COM 15 Not connected
8 ALARM1_NO Shell CHGND
18
9
15
LW3User.book Page 36 Wednesday, November 10, 1999 9:00 AM