Chapter 4 External I/O Connections 35
3. Verify the cable type used to connect external SCSI devices. You must use Fast-20
SCSI cable(s).
Ensure that the total SCSI cable length does not exceed the permissible total SCSI
bus length.
SCSI-2 (Fast Wide SCSI) External Devices
If you connect SCSI-2 (Fast Wide SCSI, 20Mbyte data transfer rate) external devices
to a Netra t 1400/1405 system, follow these cabling and configuration guidelines (as
shown in
FIGURE 4-6) to ensure proper device addressing and operation:
■ If all external mass storage devices use 68-pin connectors, connect all non-Sun
devices to the Netra t 1400/1405 system first and follow them with Sun devices.
Sun devices use auto-termination.
■ If external mass storage devices consist of 68-pin Sun devices and 50-pin devices,
connect the Sun 68-pin devices to the Netra t 1400/1405 system first and
terminate the daisy chain with the 50-pin device and its terminator.
■ The total SCSI bus length for all external SCSI devices is 6.0m (19.7ft).
FIGURE 4-6 Connecting External Mass Storage Devices
Non-Sun device
Non-Sun device
Sun device
Sun device
Sun device
50-pin device
Terminator
Adaptor cable
FL SUN 2
1400
1400