To Wire the DC Input Power Connector
1. Turn off power to the DC power source by opening the circuit breakers.
Caution Do not proceed with these instructions until you have turned off the
power to the DC power source through the circuit breakers.
2. Strip 8mm (0.31 inches) of insulation from each of the wires to be fitted to the
connector.
Do not strip more than 8mm (0.31in.) from each wire. Doing so will leave
uninsulated wire exposed from the DC input connector after the assembly is
complete.
FIGURE 3-5 Stripping the Insulation From the Wire
3. Using a DC connector from the kit, insert the tip of a cage clamp operating lever
into the rectangular hole directly above the hole in the DC connector where you
want to insert the first wire and press down on the cage clamp operating lever.
This opens the cage clamp for this section of the DC input connector.
8mm (0.31in.)
LW3User.book Page 16 Wednesday, November 10, 1999 9:00 AM