pump curve
SunPumps Centrifugal Pool Pumps
MODEL SCP 67-50-120 BC
PSI TDH TDH Motor Motor U.S. Motor
Solar Array
System
Feet Meters Voltage Amps GPM LPM Watts Watts* Efficiency
0 0 0.0 60 3.3 66.6 252 197 246 0%
2 5 1.4 60 3.4 59.7 226 205 256 25%
4 9 2.8 60 3.6 52.0 197 216 270 42%
6 14 4.2 60 3.7 41.8 158 220 275 50%
8 18 5.6 60 3.5 27.5 104 211 264 45%
10 23 7.0 60 2.4 0.0 0 146 183 0%
Suggested solar module array:
PSI TDH TDH Motor Motor U.S. Motor
Solar Array
System
Feet Meters Voltage Amps GPM LPM Watts Watts* Efficiency
0 0 0.0 75 4.5 81.7 309 336 420 0%
2 5 1.4 75 4.7 75.3 285 350 438 19%
4 9 2.8 75 4.9 68.8 260 367 458 33%
6 14 4.2 75 5.1 61.6 233 382 477 42%
8 18 5.6 75 5.2 54.1 205 388 485 49%
10 23 7.0 75 5.1 45.0 170 384 480 51%
12 28 8.5 75 4.8 31.8 120 363 454 46%
15 34 10.4 75 3.3 0.0 0 251 313 0%
Suggested solar module array:
PSI TDH TDH Motor Motor U.S. Motor
Solar Array
System
Feet Meters Voltage Amps GPM LPM Watts Watts* Efficiency
0 0 0.0 90 6.1 94.7 358 551 689 0%
2 5 1.4 90 6.3 89.9 340 567 709 14%
4 9 2.8 90 6.5 84.4 319 581 727 25%
6 14 4.2 90 6.6 78.4 297 595 744 34%
8 18 5.6 90 6.8 72.3 274 609 762 41%
10 23 7.0 90 6.9 65.7 249 617 771 46%
12 28 8.5 90 6.9 58.7 222 617 772 50%
14 32 9.9 90 6.8 50.9 193 610 763 51%
16 37 11.3 90 6.5 41.5 157 589 736 49%
18 42 12.7 90 6.1 26.2 99 545 681 38%
20.5 47 14.4 90 4.5 0.0 0 401 502 0%
Suggested solar module array:
PSI TDH TDH Motor Motor U.S. Motor
Solar Array
System
Feet Meters Voltage Amps GPM LPM Watts Watts* Efficiency
0 0 0.0 105 7.8 104.7 396 817 1021 0%
2 5 1.4 105 8.1 100.9 382 845 1057 10%
4 9 2.8 105 8.3 96.9 367 872 1089 19%
6 14 4.2 105 8.4 92.9 352 880 1100 28%
8 18 5.6 105 8.4 88.2 334 886 1108 35%
10 23 7.0 105 8.6 83.0 314 898 1122 40%
12 28 8.5 105 8.7 77.7 294 908 1135 45%
14 32 9.9 105 8.7 71.9 272 912 1141 48%
16 37 11.3 105 8.7 65.6 248 909 1137 50%
18 42 12.7 105 8.6 58.4 221 903 1129 51%
20 46 14.1 105 8.4 50.4 191 883 1104 50%
22 51 15.5 105 8.1 40.1 152 849 1062 45%
24 55 16.9 105 7.4 25.6 97 777 971 34%
26.5 61 18.7 105 5.6 0.0 0 591 739 0%
Suggested solar module array:
PSI TDH TDH Motor Motor U.S. Motor
Solar Array
System
Feet Meters Voltage Amps GPM LPM Watts Watts* Efficiency
0 0 0.0 120 9.2 113.4 429 1106 1383 0%
2 5 1.4 120 9.4 110.1 417 1132 1415 8%
4 9 2.8 120 9.9 106.9 405 1186 1482 16%
6 14 4.2 120 10.2 103.4 391 1220 1526 22%
8 18 5.6 120 10.4 100.0 379 1244 1556 28%
10 23 7.0 120 10.4 96.5 365 1249 1562 34%
12 28 8.5 120 10.4 92.6 350 1249 1562 39%
14 32 9.9 120 10.5 88.2 334 1254 1568 43%
16 37 11.3 120 10.5 83.4 316 1260 1575 46%
18 42 12.7 120 10.5 78.1 296 1265 1581 48%
20 46 14.1 120 10.5 72.5 274 1256 1571 50%
22 51 15.5 120 10.4 66.2 251 1253 1566 51%
24 55 16.9 120 10.3 59.3 224 1237 1547 50%
26 60 18.3 120 10.0 51.0 193 1199 1499 48%
28 65 19.7 120 9.6 41.2 156 1151 1439 44%
30 69 21.1 120 8.9 27.0 102 1063 1329 33%
33 76 23.2 120 6.7 0.0 0 809 1011 0%
* Solar array watts using a 20% deration factor.