Manual

IGBT TRIP ALARM
Electronics overload
Check possible causes for overload.
ALARM MESSAGE
ALARM DESCRIPTION
POSSIBLE SOLUTION
MAX. VALUE ALARM
Measured value has
reached the maximum
value accepted by the
system.
Check possible causes of reaching max
value
Check the max alarm value setting.
MIN. VALUE ALARM
Measured value has
reached the lowest
value accepted by the
system.
Check possible causes reaching min value
(i.e. broken pipe, open pressure relief
valve, etc.)
Check the min alarm value setting.
NO
COMMUNICATION
Communication
between the CM MP
and the pump has been
interrupted.
Check the wiring connections.
KEYBOARD FAULT
A Button on the
keyboard has been
pressed for more than
150 seconds
Make sure buttons are not depressed
Call service assistance
ACTIVE DIG.IN.X
Digital input X opened /
closed
Check the input digital configuration
(Installer parameters menu)