Switch User Manual

5-2 Sun Datacenter Switch 3456 Service Manual August 2008
5.1 Troubleshooting CMCs
The chassis management controllers (CMCs) have several status LEDs that can
provide some troubleshooting assistance. See
TABLE 5-1.
Additionally, the following commands can help troubleshooting CMCs:
i2ctest
clia shmstatus
clia sensordata
clia getfruledstate
5.2 Powering Off CMCs
So long as standby power is present, the CMCs are on. A CMC can’t be powered off,
but it can be deactivated with the clia deactivate command. Deactivating
means to stop administration from that CMC.
TABLE 5-1 CMC Status LEDs
Glyph Name Color State and Meaning
Attention Amber On A fault has been detected.
Off Normal operation.
Flashing A critical error has happened.
Ready-to-Remove Blue On CMC is ready to be removed.
Off Do not remove the CMC.
Flashing No function.
OK Green On CMC is operating normally.
Off No power is being supplied to the CMC.
Flashing No function.
N/A NET MGT Link
(right)
Green On Link is operating as a 100 Mbps connection.
Off Link is operating as a 10/100 Mbps connection.
Flashing No function.
N/A NET MGT Activity
(left)
Amber On Link is established.
Off No link established.
Flashing Activity on the port.